F. Vent Diagrams
Top Vent - Horizontal Termination Venting
One Elbow
Note: Use SLP Series
components only.
Note: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 5.3).
WARNING
Fire Risk.
• When using SLP-HRC-SS and SLP-HRC-ZC-
SS termination caps on top vented fi replaces,
a one foot minimum vertical vent section is
required before installing fi rst elbow.
• When using DVP-TB1 termination cap on top vented
fi replaces, a three foot minimum vertical vent section is
required before installing fi rst elbow.
Figure 7.4
Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08
V Minimum
90º Elbow
1/2 ft.
152 mm
1-1/2 ft.
457 mm
2-1/2 ft.
762 mm
3-1/2 ft.
1.1 m
4-1/2 ft.
1.4 m
H
Maximum= 15 ft. (4.6 m)
1
V
+ H
Maximum= 40 ft. (12.2 m)
1
1
H
1
H
Maximum
1
SL-750TRSFHHIPI
1 ft.
305 mm
2 ft.
610 mm
3 ft.
914 mm
5 ft.
1-1/2 m
7 ft.
2.1 m
15 ft.
4.6 m
V
1
25