3.4 Locking Ring/Tank Top Assembly
Installation
1.
Be certain the o-ring is in position in the upper
tank half. Press the filter lid over the lower half
until seated. Lubricating the o-ring with a silicone
based lubricant will help with installation (see Fig.
6).
2.
Put the locking ring/tank top assembly on the
lower housing and thread it onto the filter. Turn the
locking ring clockwise until you hear it snap over
the tabs on the lower half of the tank.
WARNING
Follow these instructions carefully.
Improper locking ring installation can
cause the filter lid to be blown off which
can result in death, serious personal
injury or property damage.
Filter Tank,
Upper Half
Locking
Ring
Locking Ring
Handle
Filter Tank,
Lower Half
Figure .
locking Ring
Section . Start-Up and Operation
DO NOT operate filter at water temperatures above
105° F (40.6° C). Water temperatures above the
manufacturer's recommendations will shorten the life
span of the filter and void the warranty.

4.1 New Pool and Seasonal Start-up

1.
Tabs
O-Ring
2.
3.
4.
5.
6.
7.
8.
WARNING
NEVER start pump while standing
within five (5) feet of the filter. Starting
the pump while there is pressurized air
in the system can cause the filter lid to
be blown off, which can cause death,
serious personal injury or property
damage.
WARNING
NEVER operate the filter system at
more than 50 psi of pressure. Operating
the filter system in excess of 50 psi can
cause the filter lid to be blown off, which
can cause death, serious personal
injury or property damage.
Caution
Turn off the filter pump and switch off the circuit
breaker to the pump motor.
Check that the filter drain cap and nut are in place
and tight.
Check that the tank locking ring is properly seated
and tight.
Open the pump hair/lint pot lid and fill the pump
basket with water to prime the system. Replace the
pump lid. You may have to do this a few times on
new and seasonal start ups.
Open the air release valve on top of the filter (do
not remove the valve).
Be sure to open any isolation valves that were
installed in the system.
Stand clear of the filter and start the pump to
circulate water through the system. When all the
air is bled from the system and a steady stream of
water starts to come out of the air release valve,
close the valve.
Watch the pressure gauge to be sure that the
pressure does not exceed 50 psi. If the pressure
approaches 50 psi, immediately turn the pump
off and clean the filter cartridges. If the pressure
remains high after cleaning the filter, refer to the
troubleshooting guide, Section 8, for possible
causes and solutions.