Section 5. Filter Disassembly And Assembly; Filter Tank Disassemby/Assembly; Filter Grid Disassembly/Assembly - Jandy DEV Series Installation And Operation Manual

Diatomaceous earth pool filters
Table of Contents

Advertisement

Page 10
WARNING
NEVER attempt to assemble,
dis as sem ble or adjust the fi lter when
there is pressurized air in the system.
Starting the pump while there is any
pressurized air in the system can
cause product failure or also cause
the fi lter lid to be blown off, which can
cause death, serious personal injury
or property dam age.
Table 3.
Valve Positions for Diverter Valve
Position
FILTER
Normal filtration and vacuuming.
BACKWASH
Cleaning filter by reversing the flow.
RINSE
Used after backwash to flush dirt
from the valve.
WASTE
Bypasses filter; used for vacuuming
waste or lowering water level.
RECIRCULATE
Bypasses filter for circulating water
to the pool.
CLOSED
Shuts off all flow to the filter and
pool.
Section 5. Filter Disassembly and
Assembly

5.1 Filter Tank Disassemby/Assembly

1.
Backwash fi lter according to the instructions in
Section 6.2.
NOTE Omit this step when fi rst starting a new fi lter.
2.
Turn off the pump. Switch off the circuit breaker
to the pump motor.
3.
IMPORTANT: Completely open air release valve
on top of the fi lter tank to release all pressure
from inside the tank and system.
4.
If the equipment is installed below water level,
close the fi lter isolation valves on the system to
prevent fl ooding.
5.
Close the fi lter isolation valves on the system to
prevent fl ooding. Remove the drain plug located at
the bottom of the fi lter tank and allow the tank to
drain.
6.
Remove the tank clamp ring from the fi lter and
remove the tank lid. Inspect the tank o-ring for
cracks or tears and replace if necessary
7.
Pull the DE fi lter grid assembly out of the fi lter
tank bottom. Use the handles molded into the
manifold to aid lifting.
Function
8.
While the DE fi lter grid assembly is out of the
fi lter tank, rinse the inside of the tank with water.
Replace drain plug.
9.
Gently rinse the grids with water. After cleaning
the fi lter grids, place the grid assembly back into
the fi lter tank bottom (see Sections 6.4 and 6.5 for
further grid cleaning instructions).
10. Replace the tank o-ring and tank lid.
11. Reinstall the tank clamp ring. See Section 3.5 for
tank clamp ring installation.
12. If applicable, open the valves closed in step 4.

5.2 Filter Grid Disassembly/Assembly

1.
Remove the complete grid assembly by following
the instructions in Section 5.1, steps 2-6.
2.
Remove the manifold by fi rst unscrewing the tie
rod knob in the center of the manifold. Then lift
the manifold assembly off of the grids and the
outlet tube.
3.
Remove the top spacer from the grids.
4.
The individual fi lter grids can now be removed
from the grid support. Use care to avoid damaging
the grids.
5.
See Figure 8 for the arrangement of fi lter grids in
the fi lter grid assembly.
6.
To reassemble the fi lter grid assembly, arrange
the fi lter grids into position on the bottom plate
(see Fig. 9). Use the plastic top spacer to hold
the grids in place.
OUTLET
PIPE WITH
O-RING
DEL
FILTER
GRID,
SHORT
SPAN
Figure 9.
Filter Grid Ar range ment
7.
Inspect the o-ring at the top of the outlet tube for
cracks or excessive wear. Replace if necessary.
8.
Assemble the manifold to the top of the assembly.
Make sure that the grids and outlet tube fi t securely
into the manifold and that the retaining rod extends
up through the hole in the center of the manifold.
BOTTOM PLATE
DEL FILTER GRID
(7 REQUIRED)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dev48Dev60

Table of Contents