Section 6: Gas Information; Fuel Conversions - Quadra-Fire TOPAZ Direct Vent Room Heater 839-1290 Owner's Manual

Direct vent room heater
Hide thumbs Also See for TOPAZ Direct Vent Room Heater 839-1290:
Table of Contents

Advertisement

6
Gas Information
A. Fuel Conversions
Before making gas connections ensure that the appliance
being installed is compatible with the available gas type.
Any natural or propane gas conversions necessary to meet
the appliance and locality needs must be made by a quali-
fied technician using Hearth & Home Technologies specified
and approved parts.
1. Converting to LP Gas
NOTE: Gas conversions should only be performed
by a qualified service person, and/or where required
by state and local codes, licensed installer/service
technician. In the Commonwealth of Massachusetts,
installation must be performed by a licensed plumber
or gas fitter.
KIT CONTENTS: Replacement orifice; replacement pilot
injector; and valve regulator.
TOOLS REQUIRED: Power drill (a 90° handle is helpful); #2
Phillips bit; 5/32 in. Allen wrench; 5/8 in. open end wrench.
Opens Left
Disconnect power and turn off gas supply if
Figure 6.1
installed. Remove front, glass, and logs if installed. Loosen
the shutter adjustment nut (located underneath the appli-
ance) with a 7/16 in. wrench. Slide the shutter to the left
(open position).
Burner Screws
Burner removal: Remove burner by first remov-
Figure 6.2
ing the two screws indicated and lifting the burner out.
September 1, 2008
Closes Right
Quadra-Fire · Topaz · 7009-113G
3 screws
Remove the three screws on the front of the burner
Figure 6.3
support. Set screws aside.
Slide the burner support to the left to access the
Figure 6.4
orifice.
Remove the main burner orifice using a 5/8 in.
Figure 6.5
wrench and replace the orifice with the proper size as indi-
cated below for your gas type and venting.
Page 23