Section 6: Gas Information; Fuel Conversions - Quadra-Fire Direct Vent Room Heater 839-1390 Owner's Manual

Direct vent room heater
Table of Contents

Advertisement

6
Gas Information
A. Fuel Conversions
Before making gas connections ensure that the appliance
being installed is compatible with the available gas type.
Any natural or propane gas conversions necessary to meet
the appliance and locality needs must be made by a quali-
fied technician using Hearth & Home Technologies specified
and approved parts.
1. Converting to LP Gas
NOTE: Gas conversions should only be performed
by a qualified service person, and/or where required
by state and local codes, licensed installer/service
technician. In the Commonwealth of Massachusetts,
installation must be performed by a licensed plumber
or gas fitter.
KIT CONTENTS: Replacement orifice; replacement
pilot injector; valve regulator; and conversion label.
TOOLS REQUIRED: Power drill (a 90° handle is help-
ful); #2 Phillips bit; 5/32" Allen wrench; 5/8" open end
wrench.
IMPORTANT NOTE! The orifice supplied with this con-
version kit is for TOP VENT MODELS ONLY. If your stove
was fitted with the rear vent kit, the correct conversion
orifice was supplied WITH THE REAR VENT KIT.
Remove front (if installed), glass, and logs (if
Figure 6.1
installed.) Using the #2 Phillips screwdriver remove the two
(2) 1/4" x 20 screws securing the burner as indicated. Lift
burner out of firebox.
September 1, 2008
Figure 6.2
screw on the pilot tower, and removing the two screws on
the front side of the burner neck support.
Figure 6.3
pilot hood and set aside.
Figure 6.4
injector.
Quadra-Fire · Sapphire · 250-7233H
Remove the burner support by loosening the left
Slide the burner neck support to the left. Pull off
Use a 5/32" Allen wrench to remove the pilot
Page 23