This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
ESD Safety Guidelines ................... 1-1 General Safety Guidelines ................1-1 An Important Note to Users ................1-2 Introduction to the SAS2-836EL Backplane............ 1-2 Chapter 2 Jumper Settings and Pin Defi nitions Front Connectors and Jumpers ..............2-1 Front Connectors .................... 2-1 Front Connector and Pin Defi...
Page 4
SAS2-836EL Backplane User's Guide Connecting Multiple Backplanes in a Dual Channel Environment ....3-11 Dual HBA Confi guration Cables ..............3-12 Supported Cascading Confi gurations ............3-13 Dual SAS HBA and Cascaded Confi guration ..........3-15 Dual SAS HBA Cascaded Confi guration with Branching ......3-16...
For faster service, RMA authorizations may be requested online (http://www. supermicro.com/support/rma/). Whenever possible, repack the backplane in the original Supermicro box, using the original packaging materials. If these are no longer available, be sure to pack the backplane in an anti-static bag and inside the box. Make sure that there is enough packaging material surrounding the backplane so that it does not become damaged during shipping.
SAS2-836EL Backplane User's Guide Chapter 1 Safety Guidelines To avoid personal injury and property damage, carefully follow all the safety steps listed below when accessing your system or handling the components. ESD Safety Guidelines Electrostatic Discharge (ESD) can damage electronic com ponents. To prevent dam- age to your system, it is important to handle it very carefully.
Introduction to the SAS2-836EL Backplane The SAS2-836EL backplane has been designed to utilize the most up-to-date tech- nology available, providing your system with reliable, high-quality performance. This manual refl ects SAS2-836EL1 and SAS2-836EL2 Revision 1.02, the most current release available at the time of publication.
SAS2-836EL Backplane User's Guide Front Connector and Pin Defi nitions 1. Primary I C Connector C Connector Pin Defi nitions The I C connector is used to monitor the power Pin# Defi nition supply status and to control the fans. See the Data table on the right for pin defi...
Page 11
SAS2-836EL Backplane User's Guide 6. Fan Connectors Fan Connectors The 3-pin connectors, designated FAN1 Pin# Defi nition through FAN3, provide power to the fans. Ground See the table on the right for pin defi ni- +12V tions. Tachometer 7. - 12. SAS Connectors...
SAS2-836EL Backplane User's Guide Explanation of Jumpers To modify the operation of the backplane, Connector Pins jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector. Pin 1 is identifi ed with...
SAS2-836EL Backplane User's Guide Rear Connectors and LED Indicators ACT#11 ACT11 SAS #3 PRI_FLASH1 C272 SAS #11 SAS #7 SAS #15 SEC_FLASH1 SAS #10 SAS #14 SAS #2 SAS #6 SAS #1 SAS #9 SAS #5 SAS #13 BCA7 SAS2-836EL2...
Page 16
SAS2-836EL Backplane User's Guide Rear LED Indicators Rear Connector Hard Drive Activity LED Failure LED SAS #0 ACT #0 FAIL #0 SAS #1 ACT #1 FAIL #1 SAS #2 ACT #2 FAIL #2 SAS #3 ACT #3 FAIL #3 SAS #4...
SAS2-836EL Backplane User's Guide Chapter 3 Dual Port and Cascading Confi gurations Single and Dual Port Expanders Single Ports SAS2-836EL1 backplanes have a single-port expander that accesses all hard drives and supports cascading. Dual Ports SAS2-836EL2 backplanes have dual-port expanders that access all the hard drives.
SAS2-836EL Backplane User's Guide Failover The SAS2-836EL2 backplane has two expanders which allow effective failover. SAS HBA Single Host Bus Adapter In a single host bus confi guration, the SEC_J2 SEC_J1 PRI_J2 PRI_J3 R284 EC15 FANFAIL_LED_DISABLE FAN_MONITOR_DISABLE PRI_J1 C154 EC20...
SAS2-836EL Backplane User's Guide Failover with RAID Cards and Multiple HBAs The SAS-836EL backplane may be confi gured for failover with multiple HBAs using either RAID controllers or HBAs to achieve failover protection. RAID Controllers: If RAID controllers are used, then the failover is accomplished through port failover on the same RAID card.
In a cascaded confi guration, the fi rst chassis includes a motherboard and at least one host bus adapter. Other servers in this enclosed system must have a power card. This section describes the supported power card for the SAS2-836EL series backplanes.
HBAs for important information on supported confi gurations. Supported Internal HBA Cables Use the following listed cables to create connections between the internal HBA and SAS2-836EL backplane. The cables required depend on the HBA connector. Cable Name: iPass to 4-lane Part #: CBL-0117L...
Page 22
Length: 39 cm (15 inches) Part #: CBL-0109L-02 Length: 22 cm (9 inches) Part #: CBL-0110L-02 Length: 18 cm (7 inches) Description: This cable has an iPass (SFF-8087/Mini-SAS) connector (36-pin) at each end. It connects from the HBA to the SAS2-836EL backplane.
SAS2-836EL Backplane User's Guide Connecting an External Host Bus Adapter to the Backplane This backplane supports external host bus adapters. In this confi guration, the HBA and the backplane are in different physical chassis. This allows a JBOD confi gura- tion system to connect to another system that has an HBA.
SAS2-836EL Backplane User's Guide Supported External HBA to Backplane Cable Use the following cable if your external HBA has an Infi niBand connector. Figure 3-8: External Cable (CBL-0166L) Cable Name: SAS EL2/EL1 Cascading Cable (External), 68 cm Part #: CBL-0166L (SFF-8088 1x to SFF-8088 x1)
SAS2-836EL Backplane User's Guide Connecting Multiple Backplanes in a Single Channel Environment This section describes the cables used when cascading from a single HBA. These connections use CBL-0167L internal cables and CBL-0166L external cables. PRI_J2 SEC_J2 SEC_J1 PRI_J3 R284 EC15...
SAS2-836EL Backplane User's Guide Single HBA Confi guration Cables Single Port Cable Assembly Figure 3-10: Single Port Internal Cable (CBL-0167L) Cable Name: SAS EL2/EL1 Backplane Cable (Internal) with 2-port Cascading Cable, 68 cm Part #: CBL-0167L (SFF-8087 to SFF-8088 x1)
SAS2-836EL Backplane User's Guide Connecting Multiple Backplanes in a Dual Channel Environment This section describes the cables used when cascading from dual HBAs. These connections use CBL-0168L internal cables and CBL-0166L external cables. PRI_J2 SEC_J2 SEC_J1 PRI_J3 R284 EC15 FANFAIL_LED_DISABLE...
SAS2-836EL Backplane User's Guide Supported Cascading Confi gurations Cascading allows the system to access data at a faster rate by allowing several backplanes to share resources to reduce latency time. The fi rst backplane in a cascaded system requires a motherboard and an HBA.
SAS2-836EL Backplane User's Guide Dual SAS HBA and Cascaded Confi guration IMPORTANT: See Section 3-3 of this manual, Failover with RAID Cards and Multiple HBAs for important information on supported confi gurations. SEC_J2 SEC_J1 PRI_J2 PRI_J3 R284 EC15 FANFAIL_LED_DISABLE FAN_MONITOR_DISABLE...
SAS2-836EL Backplane User's Guide Dual SAS HBA Cascaded Confi guration with Branching IMPORTANT: See Section 3-3 of this manual, Failover with RAID Cards and Multiple HBAs for important information on supported confi gurations. PRI_J2 SEC_J2 SEC_J1 PRI_J3 R284 FANFAIL_LED_DISABLE EC15...
Page 34
SAS2-836EL Backplane User's Guide Disclaimer (cont.) The products sold by Supermicro are not intended for and will not be used in life sup- port systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical systems whose failure to per- form be reasonably expected to result in signifi...
Need help?
Do you have a question about the SAS2-836EL and is the answer not in the manual?
Questions and answers