6. Pivot the two plastic retaining clips that secure the heat sink fan duct outward. Then remove the heat
sink fan duct from the failing heat sink and fan assembly.
Figure 127. Removing the heat sink fan duct
7. Place the new heat sink and fan assembly on the system board so that the four screws are aligned
with the corresponding holes in the system board. Ensure that you properly place the new heat sink
and fan assembly so that you can easily connect the new heat sink and fan assembly cable to the
microprocessor fan connector on the system board.
8. Follow this sequence to install the four screws to secure the new heat sink and fan assembly, as shown
in Figure 126 "Screws that secure the heat sink and fan assembly" on page 182:
a. Partially tighten screw
b. Partially tighten screw
9. Connect the new heat sink and fan assembly cable to the microprocessor fan connector on the system
board. See "Locating parts on the system board" on page 83.
.
Chapter 10
Replacing FRUs (machine types: 2756, 2800, 2929, 2932, 2934, 2941, 2945, 2961, 2982, 2988, 2993, 2996, 3181,
1
, then fully tighten screw
3
, then fully tighten screw
3183, 3185, 3187, 3198, 3202, 3207, 3209, 3214, 3218, 3224, 3227, 3306, 3393, and 3395)
2
, and then fully tighten screw
4
, and then fully tighten screw
1
.
3
.
183