Electrical Service And Repair - Heat & Glo 8000CF-OAK-IPI Owner's Manual

Installation and operation
Hide thumbs Also See for 8000CF-OAK-IPI:
Table of Contents

Advertisement

D. Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
PLUG-IN
3V TRANSFORMER
ON/OFF
WALL
SWITCH
IGNITION
MODULE
(3V)
VALVE
NEUTRAL
GROUND
BLACK WIRE CAN BE
PLUGGED INTO ANY OF
#1 - #5 LOCATIONS
ON THE HOT SIDE
Figure 12.1 Intellifi re Pilot Ignition (IPI) Wiring Diagram
44
IGNITION MODULE
FLAME SPARKER/
SENSOR
BATTERY
LOW VOLTAGE
PACK
SEE NOTE 1
REMOTE
CONTROL
HOT
WHITE WIRE
CAN BE
PLUGGED
INTO ANY
OF #1-#5
LOCATIONS
ON THE
NEUTRAL SIDE
TRANSFORMER
PLUG IN
Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. Q • 11/08
WARNING! Risk of Shock! Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.
3 VAC
RED
PIGGYBACK
ON/OFF SWITCH
3 VAC
INTERMITTENT
I
PILOT
IGNITOR
S
WHT
ORG
* GROUND TO
FIREPLACE
CHASSIS
VALVE