Blower Fan - Heat & Glo SL-550TRSI-AUE Installation And Operation Instructions Manual

Hearth and home technologies heater manual sl-550trsi-aue
Hide thumbs Also See for SL-550TRSI-AUE:
Table of Contents

Advertisement

BROWN
BLUE
Figure 31.

1.5 BLOWER FAN

These heaters have a factory installed Fan, Elec-
trical Junction Box, Variable Speed Rheostat
Control Switch and Temperature Sensor Switch
for the fan. These components are located be-
hind the lower door.
Use of the fan requires that the Junction Box
(factory installed) be connected to 240 VAC
service before permanently enclosing the heater.
The access hole for connecting the service wires
is found on the right exterior side of the unit.
See Figure 32 for wire connection detail.
24
NOTE: IF ANY OF THE ORIGINAL
WIRE AS SUPPLIED WITH THE
APPLIANCE MUST BE RE-
PLACED, IT MUST BE REPLACED
WITH TYPE 105
C RATED WIRE.
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06
BLACK
BLACK
BROWN
BLUE
TEMPERATURE
SENSOR SWITCH
GREEN/YELLOW
STRIPE
BLOWER
BLACK
(HOT) BROWN
BROWN
(NEUTRAL) BLUE
BLUE
Figure 32.
VARIABLE
SPEED
CONTROL
BLACK
240VAC JUNCTION BOX
BLUE
BROWN
GREEN/YELLOW
BROWN
BLACK
BLUE

Hide quick links: