Lexmark C925/X925 Color Product Study Guide
12. Don't Use the "Global" Import/Export method to back up the eSF applications and settings. There
is a size limit of 128kb on the export file.
13. Customers with a large number of applications or settings may exceed the file size limit and have
information truncated in the exported file.
14. Once the new RIP board is installed, follow the same steps as above, however, you will Import
(instead of export) the <filename>.UCF file for each application.

ADF Assembly

Flatbed Assembly

CCD Assembly

If the ADF, Flatbed or CCD assembly is replaced, you should perform the scanner calibration:
Resetting the Calibration Values– resets the scanner calibration values
Calibrating the Scanner Black Levels – adjusts the black levels of the scanner (this
adjustment is subjective based on what looks good to the customer).
Adjusting the ADF Magnification – adjusts the bottom margin only
Adjusting the Scanner Registration – adjusts the margins on the Flatbed scan, Front ADF
and Back ADF
Note: Skew should not need to be adjusted on this scanner as it adjusts automatically.