Extech Instruments EX210 User Manual page 13

Multimeter with ir thermometer
Hide thumbs Also See for EX210:
Table of Contents

Advertisement

Enclosure
Double molded
Diode Test
Test current of 0.9mA maximum, open circuit voltage 2.8V DC
typical
Continuity
Threshold 20 to 50Ω, test current <1.5mA
Input Impedance
10MΩ VDC/VAC
AC Response
Average responding
ACV Bandwidth
40Hz to 1000Hz
IR Spectral response
6 to 16µm
IR Emissivity
0.95 fixed
IR distance ratio
4:1
Laser pointer
Class 2 laser < 1mW power; Wavelength is 630 to 670nm
Display
2,000 count backlit liquid crystal display
Overrange indication
"OL" is displayed
Auto Power Off
15 minutes (approximately)
Polarity
Automatic (no indication for positive); Minus (-) sign for negative
Measurement Rate
2 times per second, nominal
Battery
One 9 volt (NEDA 1604) battery
Fuses
mA, µA ranges; 200mA 250V ceramic fast blow
A range; 10A 600V ceramic fast blow
Operating Temperature -10ºC to 40ºC (14ºF to 122ºF)
Storage Temperature
-10
Operating Humidity
Max 80% up to 31ºC (87ºF) decreasing linearly to 50% at 40ºC
(104ºF)
Storage Humidity
<80%
Operating Altitude
2000 meters (7000 ft) maximum
Weight
260 g (9.17oz)
Size
147x76x42 mm (5.8x2.9x1.6")
Safety
This meter is intended for origin of installation use and protected,
against the users, by double insulation per IEC/EN 61010-1:2001
and IEC/EN 61010-031:2002 to Category III 600V; Pollution
Degree 2.
Approvals
CE
Copyright © 2010 Extech Instruments Corporation (a FLIR company)
All rights reserved including the right of reproduction in whole or in part in any form.
o
o
o
o
C to 60
C (14
F to 140
F)
13
EX210-EU-EN-V2.1-08/10