Adaptation To Different Types Of Gas - Smeg Hob Instructions For The Installer

Table of Contents

Advertisement

Instructions for the installer

7. ADAPTATION TO DIFFERENT TYPES OF GAS

Before carrying out the following operations, disconnect the appliance from the
power supply.
The appliance is preset for natural gas NG at pressure of 1.0 kPa. In case of
operation with other types of gas, the burner nozzles must be changed and the
minimum flame adjusted on the gas taps. To change the nozzles, proceed as
described in the following paragraphs.
7.1
Replacing the hob nozzles
7 Extract the pan stands and remove all caps and flame-spreader crowns;
8 Unscrew the burner nozzles with a 7 mm socket spanner;
9 Proceed with the replacement of the burner nozzles according to the gas to
be used (see paragraph "7.2 Burner and nozzle characteristics table").
10 Replace the burners in the correct position.
The nozzles for using city gas (G110 – 8 mbar) are available from authorised
service centres.
20