Pacific hydrostar SUBMERSIBLE DIRTY WATER PUMP 93819 Assembly And Operating Instructions Manual
Pacific hydrostar SUBMERSIBLE DIRTY WATER PUMP 93819 Assembly And Operating Instructions Manual

Pacific hydrostar SUBMERSIBLE DIRTY WATER PUMP 93819 Assembly And Operating Instructions Manual

Submersible dirty water pump 1 hp/1.2 hp

Advertisement

SUBMERSIBLE DIRTY WATER PUMP
Model 93819 - 1 HP
Model 93820 - 1.2 HP
ASSEMBLY AND OPERATING INSTRUCTIONS
Due to continuing improvements, actual product may differ slightly from the product described herein.
Distributed exclusively by
®
Harbor Freight Tools
.
3491 Mission Oaks Blvd., Camarillo, CA 93011
Visit our Web site at: http://www.harborfreight.com
TO PREVENT SERIOUS INJURY,
READ AND UNDERSTAND ALL WARNINGS
AND INSTRUCTIONS BEFORE USE.
Copyright © 2006 by Harbor Freight Tools
. All rights reserved. No portion of this
®
manual or any artwork contained herein may be reproduced in any shape or form
without the express written consent of Harbor Freight Tools.
For technical questions, please call 1-800-444-3353.
Revised 08i

Advertisement

Table of Contents
loading

Summary of Contents for Pacific hydrostar SUBMERSIBLE DIRTY WATER PUMP 93819

  • Page 1 . All rights reserved. No portion of this ® manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. For technical questions, please call 1-800-444-3353. Revised 08i...
  • Page 2: Product Specifications

    PRODUCT SPECIFICATIONS Model Electrical Requirements Power Cord Plug Power Cord Thermal Overload Protection Switch Self-Priming Maximum Size Particle Uptake Maximum Pressure Maximum Capacity Maximum Delivery Height Maximum Submersion Depth Discharge Diameter Minimum Uptake Depth Maximum Operating Temperature You will need this manual for the safety warnings and precautions, assembly, operat- ing, inspection, maintenance and cleaning procedures, parts list and assembly diagram.
  • Page 3: Electrical Safety

    Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Power tools create sparks which may ignite the dust or fumes. Keep bystanders, children, and visitors away while operating a power tool. Distractions can cause you to lose control.
  • Page 4: Specific Safety Rules

    Maintain labels and nameplates on the Pump. These carry important information. If unreadable or missing, contact Harbor Freight Tools for a replacement. Wear ANSI approved safety impact eye goggles when assembling the Pump.
  • Page 5 Use the right product for the job. There are certain applications for which this product was designed. Do not use small tools, attachments, or equipment to do the work of larger industrial tools, attachments, or equipment. Maintain a safe environment. Keep the area well lit. Make sure there is ade- quate surrounding space.
  • Page 6 If necessary, have a certified electrician install (within 14 feet of where the Pump will be located) a 120 volt, GFCI electrical outlet that is dedicated only to the Pump. Any outlet should be above the water line. NEVER raise or lower the Pump by its electrical Power Cord. In cold weather, when the Pump is not in use, protect the interior of the Pump from freezing by draining the water and pumping a permanent type automobile anti-freeze containing a rust inhibitor through the system.
  • Page 7: Grounded Tools: Tools With Three Prong Plugs

    GROUNDED TOOLS: TOOLS WITH THREE PRONG PLUGS Tools marked with “Grounding Required” have a three wire cord and three prong grounding plug. The plug must be connected to a properly grounded outlet. If the tool should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user, reducing the risk of elec- tric shock.
  • Page 8 When unpacking, check to make sure all the parts shown on the Parts List on page 12 are included. If any parts are missing or broken, please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible.
  • Page 9 Connect the Union (37) to the Coupler (34). Make sure to hand tighten only. Over-tightening may cause the Union to crack. Then, connect a 1-1/2” diam- eter Discharge Pipe to the Union. NOTE: Make sure the Discharge Pipe is secured to a solid surface, with appropriate hardware (not included), to ensure the stability of the Pump.
  • Page 10: Inspection, Maintenance, And Cleaning

    Carefully set the Pump in place. Do not lower or raise the Pump by its Power Cord (1) or Discharge Pipe. (See Figure E.) The Float Switch (2) automatically switches on and off at a water depth of ap- proximately 4 inches. The ON/OFF height can be manually adjusted by adjusting the Float Switch Lock.
  • Page 11: Troubleshooting

    or Impeller (25) will greatly reduce performance of the Pump. To clean the Impel- ler Cover (32), spray the Cover with clean water. To clean the Impeller, remove the three Tapping Screws (39) at the bottom of the Base (38). Then, remove the Base to expose the Impeller Cover and Impeller.
  • Page 12: Please Read The Following Carefully

    PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT.
  • Page 13: Assembly Diagram

    Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. For technical questions, please call 1-800-444-3353 93819 93820 ASSEMBLY DIAGRAM NOTE: 3, 21 11, 15 Rev 08i PAGE 13...
  • Page 14: Limited 1 Year / 90 Day Warranty

    LIMITED 1 YEAR / 90 DAY WARRANTY Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that for a period of ninety days from date of purchase that the engine/motor, the belts (if so equipped), and the blades (if so equipped) are free of defects in materials and workmanship.

This manual is also suitable for:

Submersible dirty water pump 938209381993820

Table of Contents