Accessing The Gas Regulator - Thermador PALPKITHC Instructions Manual

Lp gas conversion for thermador professional cooktops and dual fuel ranges
Table of Contents

Advertisement

Available languages

Available languages

Use a 7mm -or- 9/32" socket with 1/4" driver &
extension to reach down through the venturi and
remove the Natural Gas orifice from the burner's jet
holder.
Replace each star burner jet orifice with one of the
1.15mm, LP jets supplied in the kit. These are sized for
the Star Burners to produce 15,000 BTU/hr. [4.39 kW]
flow rate using Propane (LP) Gas.
Foam Strip
Perform a brief gas leakage test of each orifice and
associated supply tube fittings, per the "Check for Gas
Leaks" section of these instructions. Proper access to
the burner's jet holder can be accomplished after main
top removal — see following section "Accessing the
Gas Regulator" for instructions on how to remove the
main top and shields.
Each orifice is stamped "115" (1.15mm orifice
diameter), as shown.
English 4

Accessing the Gas Regulator

All dual-fuel range models and cooktop models have the
gas regulator located inside the cooktop/rangetop, under
the left side of the main top.
The gas regulator is located inside the cooktop area,
typically near the left-rear corner.
Remove the cooking grates.
Remove Star Burner caps, and then remove the two
Torx screws from each burner base using a T-27 or
T-30 driver.

Advertisement

Table of Contents
loading

Table of Contents