Setting Manual Valve Screws For The Star Burners - Thermador PALPKITHC Instructions Manual

Lp gas conversion for thermador professional cooktops and dual fuel ranges
Table of Contents

Advertisement

Available languages

Available languages

Maxitrol regulator conversion:
Remove conversion cap with a 7/8" socket or wrench.
Snap-out stem from bottom of the cap, flip stem over to
show "LP" end, and snap stem back into the cap, as
shown.
Flip Stem
Re-install conversion cap —configured for LP gas—
back into top of the Maxitrol regulator.
Setting Manual Valve Screws
®
for the Star
Burners
Screw driver for valve screw setting:
A precision screwdriver with high-strength blade, similar to
the *Wiha no. 26033, with 1/8" [3.0mm] wide, .020"
[0.50mm] thickness tip, shown below, should be used to
reposition the bypass screws for minimum flow settings on
manual valves.
*Used by permission from Wiha Quality Tools division of Willi
Hahn Corporation USA.
Valve Screw
English 7