1.0 Preparation

Before starting up your high pressure wash er, we
advise you to carefully read through this instruction
manual. Fol low all instructions to min i mize the risk
of injuries when using the ma chine.

Prior to operation

Before you start up your new machine for the fi rst
time, you must mount the holder for the spray lance.
It is fi xed at the top of the transport handle.
1. Insert the holder in the recess of the handle (see
illu.).
2. Fix the holder with the screw.
1
Mount water fi lter and water inlet connection (4).
Caution: Failure to fi t the fi lter will invalidate the
guarantee.
POSEIDON 2-19 X, 2-21/2-24/2-28 XT: Mount the
handle for the hose reel.
Before starting up your machine please check it
care ful ly for any de fects. If you fi nd any, do not start
up your ma chine and con tact your Nilfi sk-ALTO
distributor.
Especially check:
• The insulation of the electric cable should be
fault less and without any cracks. If the elec tric
cable is damaged, it should be replaced by an
authorized Nilfi sk-ALTO distributor.

Mains power connection

The following should be observed when connecting
the high pressure washer to the elec tric in stal la tion:
• Only connect the machine to an in stal la tion with
earth connection.
• The electric installation shall be made by a cer ti-
fi ed electrician.
• It is strong ly rec om mend ed that the elec tric sup-
ply to this ma chine should in clude a re sid u al
cur rent device (GFCI).
Extension cable
Extension cables should be of a watertight con-
4
2
struc tion and comply with the below-men tioned
requirements for length and cable dimensions.
1.0 mm²
1.5 mm²
2.5 mm²
Only POSEIDON 2-19 X:
2.0 mm²
2.5 mm²
• Cable connections should be kept dry and off the
ground.
• Always uncoil the extension cable com plete ly to
avoid heat dam age to the cable.

Water connection

Connect the high pressure washer by means of a
water hose to the water tap (pressure of inlet wa-
ter, max. 10 bar - temperature of inlet water, max.
60°C). At tach the hose using a quick connector.
NOTE: Connection to the public mains according to
regulations.
This high pressure washer is only allowed
to be connected with the drinking water
mains, when an appropriate backfl ow
preventer has been installed, Type BA
according to EN 1717. The backfl ow preventer can
be ordered under number 106411177. The length
of the hose between the backfl ow preventer and the
high pressure washer must be at least 10 metres
(max. 25 m) to absorb possible pressure peaks (min
diameter ½ inch).
As soon as water has fl own through the BA valve,
this water is not considered to be drinking water any
more.
IMPORTANT! Only use water without any im pu-
ri ties. If there is a risk of running sand in the inlet
water (i.e. from your own well), a fi lter should be
mounted.

Safety precautions

• WARNING! High pressure jets can
be dan ger ous. Nev er direct the wa-
ter jet at per sons, pets, live elec tri cal
equip ment or the ma chine itself.
• The operator and anyone in the im-
me di ate vi cin i ty of the site of clean-
ing should take action to pro tect
them selves from being struck by
debris dis lodged
EN
max
12.5 m
max
20
m
max
30
m
máx.
12.5 m
máx.
20
m

Hide quick links: