Planning Information
Undercounter Model 249FF (I )
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications
for overall dimensions, finished rough opening
dimensions and installation specifics.
For Model 249FFI with automatic ice maker,
rough in the water supply line. Connect a
OD copper line to the house supply, being sure
to use an easily accessible shut off valve
between the supply and the unit.
Do not use self-piercing valves. A saddle
valve kit (4200880) is available from your
Sub-Zero dealer. To obtain local dealer informa-
tion, visit the Locator section of our website,
subzero.com.
A line filter is required when water condi-
tions have a high sediment content. The ice
maker operates on water pressure of 20 psi
(1.4 bar) to 100 psi (6.9 bar). In some cases a
reverse osmosis water filter system may not be
able to maintain the minimum water pressure
consistently.
Dimensions in parentheses are in
millimeters unless otherwise specified.
A 115 V AC, 60 Hz, 15 amp fused electrical
supply is required. It is recommended that a
separate circuit, serving only this appliance, be
provided.
1
/
"
All Undercounter models are equipped with a
4
power supply cord with a 3-prong grounding
plug which must be plugged into a mating
3-prong grounding type wall receptacle. Locate
electrical within the shaded area shown in the
illustration on page 3.
You must follow all National Electrical Code
regulations. In addition, be aware of local codes
and ordinances when installing your service.
Refer to the Undercounter Installation
Instructions packed with the appliance, which
provides step-by-step procedures for making
sure the unit is installed properly.