AC power

WARNING! For protection from electric shock, the fixture must be grounded (earthed). The AC mains
supply must be fitted with a fuse or circuit breaker and ground-fault (earth-fault)
protection. Check that the correct fuse is installed before applying power.

Power supply and main fuse

The MAC 700 Wash features an auto-ranging switch-mode power supply that automatically adapts to
100-120 V and 208-240 V nominal AC power at 50 or 60 Hz. However, a suitable main fuse must be
installed to match the local voltage. The MAC 700 Wash is supplied with two main fuses:
• a 6.3 AT fuse (installed) for use with AC supplies of 208 - 240 V.
• a 15 AT fuse (packed with user manual) for use with AC supplies of 100 - 120 V.
To install the correct fuse:
1. Disconnect the fixture from AC power.
2. Remove the main fuseholder, which is located beneath the power switch.
3. For operation on 208 - 240 V power, install the 6.3 A fuse. For operation on 100 - 120 V power, install the
15 A fuse.

Power connection

Important! Connect the MAC 700 Wash directly to AC power. Do not connect it to a dimmer system;
doing so may damage the fixture.
You may need to fit the power cable with a power plug that is suitable for your AC power outlets. If so, install
a grounding-type (earthed) plug following the plug manufacturer's instructions. Table 1 shows some
possible pin identification schemes; if the pins are not clearly identified, or if you have any doubts about
proper installation, consult a qualified electrician.
To apply power, first verify that the head tilt locks are released and then set the power switch on the base to
the "I" position.
Wire Color
Pin
brown
live
blue
neutral
yellow/green
ground (earth)
Table 1: Cord cap connections
Symbol
L
N
AC power
Screw (US)
yellow or brass
silver
green
7