Electrical Requirements; Gas Models - Maytag MLG2000AXW Installation Instructions Manual

Stacked washer-dryer
Table of Contents

Advertisement

ELECTRICAL REQUIREMENTS
NOTE:
Wiring diagram
is located
inside the access
panel.
Export models (not U.S. or Canada):
See Additional Instructions for Export Models on the following
pages.
GROUNDING
Each dryer must be grounded.
In the event of malfunction
or
breakdown,
the ground will reduce the risk of electrical
shock
by
providing
a path of least resistance
for electrical
current.
GAS MODELS
Each appliance
is equipped with a cord having an equipment-grounding
conductor
and a grounding
plug. The plug must be plugged into an
appropriate
outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
Do not modify the plug provided
with the appliance
- if it will not fit the
outlet,
have a proper outlet installed
by a qualified
electrician.
_WARNING
WARNING
- To prevent
unnecessary
risk of fire,
electrical
shock
or
personal
injury, all wiring
and grounding
must
be
done
in accordance
with
local
codes,
with
the National
Electrical
Code,
ANSI/NFPA
(for the United
States)
or the Canadian
Electrical
Code
CSA O22.1 (for Canada).
If a separate
ground
is required
by local codes, a grounding
kit (Part No. 12001875)
is available.
This kit
contains
the ground wire, clamp,
ground screw and washer.
Connect
ground wire to back of unit with the
cabinet ground screw and washer.
Secure
other end of ground wire to a suitable
external
ground connection.
The wire may be secured
with the clamp to a grounded
COLD metal water pipe.
NEVER
CONNECT
GROUND
WIRE TO PLASTIC
PLUMBING
LINES,
GAS LINES OR HOT WATER
PIPES.
ELECTRIC
MODELS
If a power cord is not used and the electric dryer is to be perma-
nently wired, the dryer must be connected
to a grounded
metal,
permanent
wiring system; or an equipment
grounding
conductor
must be run with the circuit conductors
and connected
to the
equipment
grounding
terminal.
U.S. Electric models are shipped
with a ground strap connected
from the neutral terminal
block post to the frame of each dryer.
If
local codes prohibits the use of the ground strap, the dryer must be
grounded
in accordance
with local codes.
Each electric dryer must be connected
to a grounded
metal,
permanent
wiring system; or an equipment
grounding
conductor
must be run with the circuit conductors
and connected
to the
equipment
grounding
terminal.
I,&WARNING
WARNING:
Improper
connection
of the
_
equipment
grounding
conductor
can result in
a risk of electric
shock.
Check
with a qualified
electrician
or serviceman
if you are in
doubt as to whether
the appliance
is
properly
grounded.
ELECTRICAL
CONNECTIONS
(see page 12 for connections)
BEFORE
OPERATING
OR TESTING,
follow
all grounding
instructions
in Grounding
Section
above.
An individual
branch
(or separate)
circuit serving
only this appliance
is recommended.
DO NOT USE AN
EXTENSION
CORD.
GAS MODELS - U.S. and Canada
A 120 volt, 60 Hz AC, approved
electrical
supply, with a 15 ampere fuse or circuit breaker
is required.
Page 6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mle2000azwMlg2000awwMle2000ayw

Table of Contents