Connecting The Power; Additional Grounding Procedure; Grounding Instruction; Connecting The Water - Thermador T24IF70NSP/99 Installation Instructions Manual

Built-in refrigerators, freezers and wine units single door models
Table of Contents

Advertisement

Connecting
the power
Electrical
Shock
Hazard
- Plug into a grounded
3 prong outlet.
- Do not remove ground prong.
- Do not use an adapter.
- Do not use an extension
cord.
Failure to follow these instructions
can result in
death, fire, or electrical shock.
The appliance
comes with a 3-wire power supply cord,
UL listed in the USA.
The appliance
requires a 3-wire receptacle.
The receptacle
must be installed by a licensed
electrician
only.
The receptacle
must be fitted with a 10A fuse or higher.
Please observe in this coherence
the following
table:
Appliance
Refrigerat0r24"
Refrigerator 3 0"
Freezer18" (incl, IceMaker)
Freezer 24" (incl, IceMaker)
Freezer 30" (incl, IceMaker)
Maximum load at one time
2 Ampere
2 Ampere
3,5 Ampere
4 Ampere
4,5 Ampere
Orient ground prong to the bottom
as shown in the
pictures.
For the installation
position of the receptacle
see
"Installation
dimensions",
page 8.
Additional
grounding
procedure
Some local regulations
may require a seperate ground.
In such cases, the required accesseory
ground wire,
clamp and screw must be purchased
seperately.
Never ground the appliance
to plastic plumbing
lines,
gas lines or water pipes.
Grounding
instruction
This appliance
must be grounded.
In the event of
a malfunction
or breakdown,
grounding
will reduce
the risk of electric shock by providing
a path of least
resistance for the electric current.
Improper
connection
of the equipment
grounding
conductor
may result in electric shock. Have the
appliance
checked
by a qualified electrician
or
service technician
if you are in doubt as to whether
the appliance
has been properly grounded.
Connecting
the water
A cold water connection
is required for operation
of
the automatic
ice maker. The water pressure
must
be between
25 and 120 p.s.i. (1.72-8.25
bar).
The installation
must comply with local plumbing
regulations.
A separate shut-off valve must be installed for the
appliance
water connection.
The shut-off valve for the water connection
must not be
behind the appliance.
It is recommended
to place the
shut-off valve directly next to the appliance
(base unit)
or in another easily accessible
location.
When installing the water connection,
observe the
permitted
installation
areas for the pipe. For the
permitted
installation
areas and dimensions
see
"Installation
dimensions",
page 8.
The supply pipe can be located at the side on the right
(a), at the side on the left (b) or underneath
(c).
Maximum outer diameter of the water pipe
(without fittings):
13/32"
(10 mm).
Attach a separate shut-off valve for the water
connection
in a suitable, easily accessible
location.
Do not use a self-piercing
valve!