GENERAL WATER SOFTENER MAINTENANCE, continued
CLEANING
THE NOZZLE
AND VENTURI ASSEMBLY
..............................
A clean nozzle and venturi
is needed for the soft-
ener to work
right. This small unit makes the suc-
tion to move brine from the salt storage
area to the
resin
tank
during
regeneration.
If
it
becomes
plugged with sand, silt, dirt, etc., the softener
will not
work and you will get hard water.
To get to the nozzle and venturi,
remove the softener
top cover. Be sure the softener
is in service
cycle (no
water
pressure
at nozzle
and venturi).
Then, while
holding
the nozzle
& venturi
housing
with 1 hand,
turn
off the cap.
Lift out the screen
support
and
screen,
then the nozzle and venturi.
Wash and rinse
the parts in warm water until clean.
If needed,
use
a small brush to remove iron or dirt. Also check and
clean the gasket.
NOTE:
Some models have a smarl flow plug located
in the
nozzle
and venturi,
and/or
a small
cone
shaped
screen in the housing.
Be sure to check and
clean these parts, if your model
is so equipped.
Carefully
replace
all parts in the correct order. Lubri-
cate the o-ring seal with silicone
grease
and place
in position.
Install
and tighten
the cap, BY HAND
ONLY. DO NOT OVER-TIGHTEN
AN D BREAK THE
CAP OR HOUSING.
can_
O-ring
Seal _
Screen Support
_.......,_._@
Screen _
/_'_
_
*Flow Plug
Nozzle & Venturi _
_'J
(1-EP)
Gasket _"_
,_
Screen
IMPORTANT=
Be sure _
_
holes in the gasket
are cen-
tered directly
over the small
holes in the nozzle & venturi
housing.
*Flow Plug
(HVDC)
Nozzle & Venturi
Housing
*INSTALL
WITH NUMBERED
SIDE
UP CONCAVE SIDE DOWN. Seeiden-
tification chart on page 24.
SERVICE CHECKLIST
No salt in storage tank: See page 15 to refill, then
start a regeneration, or recharge.
Transformer
unplugged
at wall outlet,
or power
cable disconnected:
Reconnect
to electrical pow-
er and start a regeneration,
or recharge.
Fuse blown,
circuit
breaker
popped,
or circuit
mistakenly
switched
off:
Check
and resolve
as
needed.
Then, start a regeneration,
or recharge.
Plumbing
bypass valve(s)
in "bypass"
position:
Refer to page 6 and position valve(s)
as needed to
direct soft water to house pipes. Then, start a regen-
eration,
or recharge.
Timer
not programmed:
See page 10.
Nozzle
& venturi
dirty, or salt in storage
tank
bridged:
See page 15, and above to clean. Then,
start a regeneration,
or recharge.
16