Accu Spot 250 Hybrid
This unit comes with interchangable gobos. Changing the
gobos is a easy procedure. Follow the instructions below.
Caution! Never open the unit when in use. Always disconnect
the main power before attempting to change the gobos.
1. To change the gobo, you must remove the top half of the
moving head. The top half of the moving head does not have
the lens in front. The lens is on the bottom half of the head.
2. First start by removing the front metal plate by unscrewing
the four phillips screws. Now, unscrew the two phillips
screws in the front of the moving head and the two in the
back. Remove the top half of the shell.
3. When you remove the shell you will be able to access the
gobo wheel. Turn the wheel with your hand until you come
across the gobo you would like to change.
4. With your finger push the gobo out towards the front and
then slide the gobo up and out of the wheel. When doing this
you do not need a lot of pressure.
5. Change the gobo by sliding the new gobo into place and
reassemble the shell.
Note: If you want to add your own custom gobo, you will
have to remove the retainer ring that secures the gobo to
the gobo frame. Remove the retainer ring using your finger
nail or flat head screwdriver. Secure your gobo to the gobo
frame using the retainer ring and slide the new gobo into
place in the wheel.
American DJ
- www.americandj.com - Accu Spot 250 Hybrid Instruction Manual Page 45
®

Gobo Replacement

Accu Spot 250 Hybrid
Fixture Cleaning:
Due to fog residue, smoke, and dust cleaning the
internal and external optical lenses and mirror should be carried out
periodically to optimize light output. Cleaning frequency depends on
the environment in which the fixture operates (I.e. smoke, fog residue,
dust, dew). In heavy club use we recommend cleaning on a monthly
basis. Periodic cleaning will ensure longevity, and crisp output.
1. Use normal glass cleaner and a soft cloth to wipe down the out-
side casing.
2. Use a brush to wipe down the cooling vents and fan grill.
3. Clean the external optics and mirror with glass cleaner and a soft
cloth every 20 days.
4. Clean the internal optics with glass cleaner and a soft cloth every
30-60 days.
5. Always be sure to dry all parts completely before plugging the unit
back in.
Accu Spot 250 Hybrid
Trouble Shooting: Listed below are a few common problems that
you may encounter, with solutions.
No light output from the unit;
1. Be sure you have connected your unit into a standard 120v wall
outlet.
2. Be sure the external fuse has not blown. The fuse is located at
the rear of the unit.
3. Remove the lamp holder and be sure the lamp is seated in its
socket properly. Occasionally lamps become loose during ship-
ping be sure the lamp is push in to its socket all the way.
4. Be sure the fuse holder is completely and properly seated.
Unit does not respond to sound;
1. Low frequencies (bass) should cause the unit to react to sound.
Tapping on the microphone, quiet or high pitched sounds may
not activate the unit.