Long Term Storage Of Your Heater - Dyna-Glo RMC-KFA50DGD User's Manual And Operating Instructions

Indoor/outdoor kerosene portable forced air heaters
Table of Contents

Advertisement

NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
NOTICE : The major electrical components of this heater are protected by a safety fuse mounted to the PCB board.
If your heater fails to start, check this fuse first and replace as necessary.
power source to insure that proper voltage and frequency are being supplied to the heater.
TO STOP HEATER
1. Turn switch to "OFF" and unplug power cord.
TO RESTART HEATER
1.Wait 10 seconds after stopping heater.
2. Repeat steps under to start heater.
EXTRA ELECTRIC OUTLET & PIGGYBACK POWER CORD
WARNING : SHOCK HAZARD!
• Always cover electric outlet
when not in use.
• Don't plug and use a appliance
more than 120V/60Hz 5A
current in this outlet

8. LONG TERM STORAGE OF YOUR HEATER

FUEL TANK DRAIN
1. Drain fuel tank through fuel cap opening.
(For RMC-KFA50DGD/75TDGD Models Only)
2. Remove fuel drain bolt from rear bottom side of fuel tank using 3/4" socket or adjustable wrench and drain.
(For RMC-KFA125/170/210TDGD-01 Models Only. See Figure 10)
3. Using a small amount of kerosene, swirl and rinse the inside of the tank.
NEVER mix water with the kerosene as it will cause rust inside the tank.
Pour the kerosene out making sure that you remove it all.
IMPORTANT : Do not store kerosene over summer months for use during next heating season.
4. Reinstall fuel cap. Properly dispose of old and dirty fuel. (For RMC-KFA50DGD/75TDGD Models Only)
5. Reinstall fuel drain bolt to Fuel tank and tighten firmly using 3/4" socket or adjustable wrench.
(For RMC-KFA125/170/210TDGD-01 Models Only. See Figure 10)
IMPORTANT : Before reinstalling the fuel drain bolt, make sure the seal is on the bolt. If the seal is
6. Store heater in dry well ventilated area. Make sure storage place is free of dust and corrosive fumes.
7. Store the heater in the original box with the original packing material and keep the USER'S MANUAL
with the heater.
Outlet
RMC-KFA210TDGD-01 Model Only
Using old fuel could damage heater.
not used the bolt cannot be installed correctly and the fuel tank will leak.
Figure 10. Fuel Drain Bolt
C
o
v
r e
Figure 9. Electric Outlet
Seal
Fuel Drain Bolt
9
You should also check your
C
o
v
r e
RMC-KFA75TDGD/125/170TDGD-01 Models only
Outlet