MOuNTaiNeer
model VG650ELG
READ ALL INSTRUCTIONS CAREFULLY
BEFORE STARTING THE INSTALLATION
OR OPERATING THE STOVE. FAILURE TO
FOLLOw INSTRUCTIONS mAY RESULT IN
PROPERTY DAmAGE, BODILY INjURY, OR
EVEN DEATH.
SAFETY INSTRUCTIONS
SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE/BUILDING FIRE
mAY RESULT. FOR YOUR SAFETY, CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT
PERmITS, RESTRICTIONS, AND INSTALLATION REqUIREmENTS FOR YOUR AREA.
READ ALL INSTRUCTIONS CAREFULLY.
1. The installation of this stove must comply
with your local building code rulings. Please
observe the clearances to combustibles (see
reference figures 7– 9). Do not place furni-
ture or other objects within the clearance
area.
2. Verify that the stove is properly installed
before firing the stove for the first time.
After reading these instructions, if you have
any doubt about your ability to complete
your installation properly, you must ob-
tain the services of a professional licensed
installer familiar with all aspects of safe
and correct installation. DO NOT use
temporary or makeshift compromises
during installation.
3. DO NOT store wood, flammable liquids
or other combustible materials too close to
the unit. Refer to certification label on back
of unit and reference figures 7 – 9 in this
manual.
4. DO NOT INSTALL THIS STOVE
IN A mOBILE HOmE, mANUFAC-
VGZ-025 | 201110519.0
(save this manual for future reference)
Vogelzang International Corp.
WOOdsTOve
™
Owners manual
DO NOT USE THIS STOVE IN A mOBILE
HOmE, mANUFACTURED HOmE, TRAILER
OR TENT — NO EXCEPTIONS!
This stove meets
U.S. Test Standard:
UL 1482-1996
TURED HOmE, TRAILER OR TENT
NO EXCEPTIONS!
24 CFR Ch.XX).
5. If any parts are missing or defective, please
notify the dealer or manufacturer immediately.
DO NOT OPERATE A STOVE THAT IS
mISSING ANY PARTS!
6. Do not tamper with combustion air control
beyond normal adjustment capacities.
7. Always connect this stove to a chimney and
vent to the outside. Never vent to another
room or inside a building. DO NOT CON-
NECT THIS UNIT TO A CHImNEY FLUE
SERVING ANOTHER APPLIANCE.
8. Do NoT coNNecT a wood burning stove
to an aluminum Type B gas vent. This is not
safe. Use code-approved lined masonry or
a UL 103 HT Listed Residential Type and
Building Heating Appliance chimney. Use
a 6" diameter chimney or larger, that is high
enough to give a good draft. (See specifics in
installation instructions).
Vogelzang International Corporation
400 West 17th Street
Holland, Michigan 49423
www.vogelzang.com
Phone: 1-616-396-1911
Fax: 1-616-396-1971
VG650ELG MountainEEr™ |
(HUD Federal Standard:
continued on next page
Page 1
Need help?
Do you have a question about the Mountaineer VG650ELG and is the answer not in the manual?
Questions and answers
Do you have a picture of inside the box? Are there supposed to be bars across the top for circulation?
The Vogelzang International Mountaineer VG650ELG includes various parts such as the stove body, heat shield, blower assembly, flue collar, flue damper, ash cleanout cover, stove door frame, door handle assembly, high-temp ceramic glass, glass retainer, glass retainer screws, complete door assembly (less handle), pedestal components, fire brick pack, blower housing, blower/motor, and other hardware.
The provided context does not mention bars across the top for circulation.
This answer is automatically generated
Is there anything to help with draft other than damper?
When installing the damper you will need to drill a whole in the stove pipe also? If you install through collar you will need to drill a hole in new stove pipe also .If not damper will open or close correctly. Right?
The manual does not mention drilling a hole in the stove pipe for damper installation. It instructs to install the damper into the collar and insert the damper handle through the collar into the damper and out the opposite side.
This answer is automatically generated