Chimney Connections; Masonry Chimney - Vogelzang International Mountaineer VG650ELG Owner's Manual

Hide thumbs Also See for Mountaineer VG650ELG:
Table of Contents

Advertisement

ChImNEY CONNECTIONS

The stove must be connected to either a ma-
sonry or manufactured metal chimney built and
tested to the specifications listed on the previous
pages.
Chimneys perform two functions:
1). As a means of exhausting smoke and flue
gases which are the result of fuel combustion.
2). The chimney provides "draft" which allows
oxygen to be continuously introduced into the
appliance, so that proper combustion is possible.
This stove relies on natural draft to operate.
NOTICE: Always provide a source of fresh air
into the room where the stove is located. Failure
to do so may result in air starvation of other fuel
burning appliances and the possible development
of hazardous conditions, fire or death.
Your stove itself does not create draft. Draft is
provided by the chimney. To achieve proper draft
your chimney must meet the three minimum height
requirements detailed in figures 12–14. A minimum
of 0.05 w.c. (measured in water column) is required
for proper drafting to prevent back puffing, smoke
spillage, and to maximize performance. (Gauges to
measure draft are readily available at stove stores
and are economical to rent or purchase.)
Factors such as wind, barometric pressure,
trees, terrain and chimney temperature can have
an adverse effect on the draft. The manufacturer
cannot be held responsible for external factors
leading to less than optimal drafting.
Should you have a problem with inadequate
draft, you should contact a licensed heating and
cooling contractor for assistance in solving the
problem.
ImPORTANT Installation Points
1. Size chimney flue to stove collar. This stove
requires a 6" diameter flue.
2. Never connect this unit to a chimney serv-
ing another appliance.
3. The chimney must meet all minimum
height requirements.
4. Never use a chimney to ventilate a cellar
or basement.
5. Contact your local building authority
for approved methods of installation and any
necessary permits and/or inspections.
Page 8
| VG650ELG MountainEEr™

Masonry ChiMnEy

Before using an existing masonry chimney,
clean the chimney, inspect the flue liner and make
any repairs needed to be sure it is safe to use. Make
repairs before attaching the stove. The connec-
tor stove pipe and fittings you will need to con-
nect directly to a masonry chimney are shown in
figure 11.
THIMBLE
COLLAR
6˝ ROUND
24 ga. BLACK
STOVEPIPE
Fig. 11 - Masonry Chimney Connection
If the connector stove pipe must go through
a combustible wall before entering the masonry
chimney, consult a qualified mason or chimney
dealer. The installation must conform to local
building and fire codes and latest edition of NFPA
211.
If there is a cleanout opening in the base of the
chimney, close it tightly.
Fig. 12 - Chimney Construction Through Attic Space
www.vogelzang.com
8˝ MIN.
LINER
BELOW
ENTRY
HOLE
VGZ-025 | 201110519.0
CHIMNEY
FLUE
5/8" TILE
CHIMNEY
LINER
MASONRY
CHIMNEY