PROXIMITY
TO SIDE CABINETS
1. This range may be installed directly adjacent to existing 36" (914 mm) high base
cabinets.
2.
3.
Range
dimensions:
• width: 23" 7/8 (606.5 mm)
• depth: 24" 5/64 (611.6 mm)
• height (without backguard):
MIN 35" 7/16 (900 mm) - MAX 36" 7/32 (920 mm)
• backguard (height): 4" 7/16 (113 mm)
Gas line opening:
Wall - 5" 57/64 (150 mm) from the floor; 11" 15/16 (303 mm) from the rear left side
of the range.
Grounded
outlet: the electric cord with 3-prong
ground plug has a length of 72"
(1830 mm). Grounded
outlet should be located
5" 57/64 (150 mm) from the floor
and 11" 15/16 (303 mm) from the rear right side of the range.
The range CANNOT be installed
directly adjacent to sidewalls, tall cabinets,
tall
appliances, or other side vertical surfaces above 36" (914 mm) high.
There must be a minimum of 3" (76 mm) side clearance from the
range
to such
combustible
surfaces TO THE LEFT above the 36" (914 mm) high countertop;
or
there must be a minimum of 11" 13/16 (300 mm) side clearance from the range to
such combustible
surfaces TO THE RIGHT above the 36" (914 mm) high counter-
top.
IMPORTANT: One side (left or right) above the 36" (914 mm) high countertop
must always be kept clear.
The maximum upper cabinet depth recommended
is 13" (330 mm). Wall cabinet
above the range must be a minimum
of 30" (762 mm) above the countertop
for a
width of minimum 24" (609.6 mm): it has to be centred with the range. Side wall cab-
inets above the range must be a minimum of 18" (457 mm) above the countertop.
GAS AND ELECTRIC
CONNECTION
Area for GAS connection
-_
Dotted line showing the position
of the range when installed
/
6