INJECTORS
TABLE
NOMINAL
POWER
BURNERS
BTU/hr
Auxiliary (AUX)
3500
Semirapid (SR)
6000
Triple ring (TC)
12000
Oven burner
13000
Broil burner
8500
REDUCED
LP/PROPANE
NATURAL GAS
POWER
11"W.C.R
4"W.C.P.
BTU/hr
0 injector
By-pass
0 injector
By-pass
[1/100mm]
[1/100 mm]
[1/100mm]
[1/100 mm]
1000
55
27
90
adjustable
1500
72
32
118
adjustable
5000
102
65
170
adjustable
1500
109
34
180
adjustable
88
146
Fig.2.8
OPERATIONS
TO BE PERFORMED
WHEN SUBSTITUTING
THE INJECTORS
,/ Remove the gratings, the burner covers and the knobs;
,/ Using a wrench substitute the nozzle injectors "J" (figs. 2.7 - 2.8) with those most
suitable for the kind of gas for which it is to be used.
The burner are conceived
in such a way so as not to require the regulation of the
primary air.
Fig. 2.9
SETTING
THE BURNER
MINIMUM
When switching from one type of gas to another, the minimum flow rate must also be
correct: the flame should not go out
even when passing suddenly from maximum to
minimum flame.
To regulate the flame follow the instructions
below:
- Light the burner
- Set the gas valve to LO position
- Remove the knob
- With a thin screwdriver
pass by the hole of microswitch
and turn the screw F until
adjustment
is correct (fig. 2.9).
For LP/PROPANE gas, tighten the adjustment
screws completely.