Fisher & Paykel OR24SDMBGX Installation Instructions Manual page 16

Hide thumbs Also See for OR24SDMBGX:
Table of Contents

Advertisement

Available languages

Available languages

I
Fig. 2.14
]
ADJUSTMENT
OF THE OVEN BURNER
MINIMUM
This needs to be done only for the oven burner (the broil is a fixed capacity) by acting
on the thermostat
in the following way:
- Turn on the burner by setting the thermostat
knob on position 8.
- Remove the knob and unscrew the by-pass screw "G" (fig. 2.14) about three times
by passing a small flat screwdriver (0 3 mm blade, 100 mm length) through the panel
opening.
- Re-mount the knob and let the oven heat up for about 10 minutes, then bring the knob
to position 1 (minimum) to operate the thermostat by-pass.
- After having removed the knob again and being very careful not to turn the tap rod,
slowly screw the by-pass screws "G" (fig. 2.14) until you obtain a flame of 3-4 mm
in height.
N.B. For LP/PROPANE
gas the by-pass screw must be fixed thoroughly.
After regulation repeat the operations indicated in paragraph "2. Pressure regulator" at
page 9 and 12.
If the range has been disconnected
and then connected
again to the gas supply line
repeat the operations
indicated in paragraph "5. Leak Testing" at page 12.
IM PO RTANT"
After conversion to LP/PROPANE gas has been carried out affix inside the drawer, near
the data plate, the conversion label supplied and also affix a conversion label at page
3 of this instruction
manual.
16