Casio fx-7400G PLUS Booklet page 45

Graphic calculator - a booklet of practical examples for students
Hide thumbs Also See for fx-7400G PLUS:
Table of Contents

Advertisement

Program for the 1-Phase Excitation System
Filename:STEP-1
S-WindAuto ↓
ClrGraph ↓
{0} → List 6:Send (List 6) ↓
{1,6,4,1,2,4,8} → List 6:Send (List 6) ↓
{3,0.2,48,0,0} → List 6:Send (List 6) ↓
{1,1,2,2,5,5,6,6,9,9,9,9,8,8,7,7,4,4,3,3,1} → List 1 ↓
{7,8,8,7,7,8,8,7,7,8,2,3,3,4,4,3,3,4,4,3,3} → List 2 ↓
{9,7,7,6,6,3,3,2,2,1,1,1,4,4,5,5,8,8,9,9} → List 3 ↓
{5,5,6,6,5,5,6,6,5,5,7,1,1,2,2,1,1,2,2,1} → List 4 ↓
S-Gph1 DrawOn,xyLine,List 1,List 2,1,Dot ↓
S-Gph2 DrawOn,xyLine,List 3,List 4,1,Dot ↓
S-Gph3 DrawOff ↓
DrawStat
Program for the 2-Phase Excitation System
Filename:STEP-2
S-WindAuto ↓
ClrGraph ↓
{0} → List 6:Send (List 6) ↓
{1,6,4,3,6,12,9} → List 6:Send (List 6) ↓
{3,0.2,48,0,0} → List 6:Send (List 6) ↓
{0,0,2,2,4,4,6,6,8,8,9,9,8,8,6,6,4,4,2,2,0,0} → List 1 ↓
{7,8,8,7,7,8,8,7,7,8,8,3,3,4,4,3,3,4,4,3,3,4} → List 2 ↓
{9,9,7,7,5,5,3,3,1,1,0,0,0,1,1,3,3,5,5,7,7,9,9,9} → List 3 ↓
{6,5,5,6,6,5,5,6,6,5,5,7,2,2,1,1,2,2,1,1,2,2,1,3} → List 4 ↓
S-Gph1 DrawOn,xyLine,List 1,List 2,1,Dot ↓
S-Gph2 DrawOn,xyLine,List 3,List 4,1,Dot ↓
S-Gph3 DrawOff ↓
DrawStat
Program for the 1-2-Phase Excitation System
Filename:STEP-1-2
S-WindAuto ↓
ClrGraph ↓
{0} → List 6:Send (List 6) ↓
{1,6,8,1,3,2,6,4,12,8,9} → List 6:Send (List 6) ↓
{3,0.2,96,0,0} → List 6:Send (List 6) ↓
{0,0,3,3,8,8,9,9,7,7,4,4,0} → List 1 ↓
{7,8,8,7,7,8,8,3,3,4,4,3,3} → List 2 ↓
{9,5,5,2,2,0,0,0,1,1,6,6,9,9,9} → List 3 ↓
{5,5,6,6,5,5,7,2,2,1,1,2,2,1,3} → List 4 ↓
S-Gph1 DrawOn,xyLine,List 1,List 2,1,Dot ↓
S-Gph2 DrawOn,xyLine,List 3,List 4,1,Dot ↓
S-Gph3 DrawOff ↓
DrawStat
M-2 Stepping Motor Excitation Systems
• Program name: STEP-1
• Specifies auto setup of the graph screen range.
• Clears the graph.
• Inputs the data inside {} into List 6, and sends
the List 6 data to the Data Analyzer. {0}: All clear
/ {1,6,4,1,2,4,8}: Sends 4 data elements to
DIGOUT. / {3,0.2,48,0,0}: 0.2-second sampling
interval, 48 samples, trigger disabled (immediate
execution)
• Graph data
• Graph 1 is xy (List 1, List 2) graph.
Graph 2 is xy (List 3, List 4) graph.
Graph 3 not displayed
Graph produced using list data.
• Program name: STEP-2
• {1,6,4,3,6,12,9}: Sends 4 data elements to
DIGOUT. / {3,0.2,48,0,0}: 0.2-second sampling
interval, 48 samples, trigger disabled (immediate
execution)
• Graph data
• Program name: STEP-1-2
• {1,6,8,1,3,2,6,4,12,8,9}: Sends 8 data elements to
DIGOUT. / {3,0.2,96,0,0}: 0.2-second sampling
interval, 96 samples, trigger disabled (immediate
execution)
• Graph data
– 42 –

Advertisement

Table of Contents
loading

Table of Contents