Verify Package Contents
Hold down brackets (2)
Grates (2 for RGC304, 3 for RGC365)
Burner sets (4 for RGC304, 5 for RGC365)
Gas pressure regulator
Stainless steel cleaner (stainless steel models only)
If any parts are missing, see the Parts List section on
page 10 for ordering information.
Installing the Cooktop
WARNING
Verify that the power supp!y meets the specifications
on page 4 before proceedingl
To prevent damage to the gas pressure regulator,
instal! it only after the cooktop iS mounted in its per-
manent position.
@ IMPORTANT
-
DO nOt oVer:tighte_own
bolts: Over tight-
ening
the hold down b01ts may result in improper
operat!on of the dual gas burners:
D0not Use a hardening COmpOund 0r Caulk t0 perma,
nently Seal the c00kt0p int0 place: The Cooktop must
be readily rem0vable if service is required; Removal
0f sealan! t0 SeW!ce the Unit W I be performed at the
cUstOmers
expense:
1.
If the cooktop will be used with a raised vent, install the
vent according to it's installation instructions first.
2.
Lower the cooktop into the cutout and center it.
3.
Secure the cooktop to the countertop using the two (2)
provided hold-down brackets as shown.
\
Hold down bracket
_'
mounting holes"
9
/
(both sides)
Gas inlet
//
/
Electriccord
/
Hold Down Bracket
Installation
Connecting the Gas Line
WARNING
o
Verify that the gas supply meets specifications before
connection, See page 4,
o
Do not install or use the cooktop without the included
gas regulator installed,
Ensure that the arrow on the regulator points in the
direction of the gas flow, towards the cooktop.
-
Do not apply excessive pressure when tightening gas
connections and fittings.
Do not use Teflon tape or plumber's putty on flexible
gas line connections.
-
Test the gas lines for leaks as instructed before use.
Do not use a flame to check for leaks.
The maximum gas supply pressure to the regulator
must never exceed 1/2 pounds per square inch (psi)
or 3.5 kPa.
The cooktop and shut-off valve must be disconnected
from the gas supply piping system during any pres-
sure testing exceeding 1/2 psi (3.5 kPa).
The cooktop must be isolated from the gas supply
piping system by closing the shut-off valve to the
cooktop during any gas supply piping system pres-
sure testing equal to or less than 1/2 psi (3.5 kPa).
For LP gas installations, the LP gas tank must have
its own high-pressure regulator in addition to the
pressure regulator supplied with the cooktop.
.
.
Attach the gas pressure regulator (included with the
cooktop) to the cooktop pipe nipple inlet. For tight
installations, the regulator may be installed upstream
from the pipe nipple, anywhere between the shut-off
valve and the cooktop. For best performance, minimize
gas pressure loss by attaching the regulator as close
as possible to the cooktop gas inlet.
Complete connection of the gas supply to the cooktop
by installing a minimum 1/2" flexible gas line (not
included) between the pressure regulator and the shut-
off valve.
3.
Check for gas leaks:
0
0
Turn all cooktop control valves to the OFF position.
Turn on the gas supply valve and check all lines
and connections for leaks using a soap and water
solution or a gas leak detector.
0
Turn the gas supply off.
_a_D_