Frigidaire PLCF489GCA Installation Instructions Manual page 4

40" dual fuel range
Hide thumbs Also See for PLCF489GCA:

Advertisement

Available languages

Available languages

2. Remove t he3 loose nuts(afteryouremoved t he
rubber band) ontheterminal b lockusing3/8" nut
driveror socket.
3.Connect theneutral w hitewireofthe copper p ower
supply cordto thecentersilver-colored terminal o fthe
terminal b lock, a ndconnect t heotherwiresto the
outerterminals. Match wiresandterminals bycolor
(redwiresconnected t o therightterminal, b lackwires
connected t o theleftterminal).
4. Replace the 3 nutsontheterminal b lock(see figure
3).
5. Lower t he terminal c overandreplace the 3 screws.
Silver colored Terminal
Red wi re
6. Replace the 3 nuts on the terminal block (see fig. 4).
7. Lower the terminal cover and replace the 3 screws.
Block
Silver Colored
Terminal
1-1/8"
Dia.
Direct
Connection
Hole. Punch
out knockout
for 1-3/8"
Dia.
Cord Kit Hole
Terminal
Block
Black
wire
A user
supplied
strain-relief
must be installed
To 240 V receptacle
at this location
d_t
NOTE: Be sure to remove the supplie
grounding
strap
Figure 4
A
supplied by the user
must be installed at
this location
To 240 V
receptacle
Figure 3
1-1/8" Dia.
Direct
Connection
Hole. Punch
out knockout
for 1-3/8" Dia.
Cord Kit Hole
Four Conductor
Wire
Connection
to Range
(mobile
homes)
1. Remove the 3 screws at the lower end of the rear wire
cover, then raise the lower end of the rear wire cover
(access cover) upward to expose range terminal
connection block (see figure 2).
2. Remove the three loose nuts (after you removed the
rubber band) on the terminal block using a 3/8" nut
driver or socket.
3. Remove the grounding strap from the terminal block
and from the appliance frame.
4. Connect the ground wire (green) of the copper power
supply cord to the frame of the appliance with the
ground screw, using the hole in the frame where the
ground strap was removed (see Figure 4).
5. Connect the neutral of the copper power supply cord
to the center silver-colored terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red
wires connected to the right terminal, black wires
connected to the left terminal).
Direct
Electrical
Connection
to the Circuit
Breaker,
Fuse Box or Junction
Box
If the appliance is connected directly to the circuit breaker,
fuse box or junction box, use flexible, armored or non
metallic sheathed copper cable (with grounding wire).
Supply a U.L. listed strain-relief at each end of the cable.
At the appliance end, the cable goes through the Direct
Connection Hole (see figure 4) on the Cord Mounting
Plate. Wire sizes (copper wire only) and connections must
conform to the rating of the appliance.
Where local codes permit connecting
the appliance
grounding
conductor
to the neutral
(white)
wire
(see Figure 5).
(The 3-conductor
cord or cable must be replaced with a
4-conductor cord or cable where grounding through the
neutral conductor is prohibited in new installations,
mobile homes, recreational vehicles or in other areas
where local codes do not permit neutral grounding)
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box:
a) Connect the green (or bare copper) wire, the white
appliance cable wire, and the neutral (white) wire
together.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
4