Model and Serial Number Location
Theserial p lateislocated onthe oven frontframebehind
the large ovendoor.
Whenordering partsforor making inquiries aboutyour
range, a lways besureto include the model a ndserial
numbers a nda lot number o r letterfromtheserial p late
onyourrange (Figure 1).
Serial P lateLocation
2. Access to Terminal
Block &
Grounding
Strap
To gain access to lower
terminal block bend lower
back cover plate along row
of holes shown here
Pressure
regulator location
Figure 2
Figure 1
1. Power Supply Cord Kit
The user is responsible for connecting the power supply
cord to the connection block located behind the back
panel access cover.
This appliance may be connected by means of
permanent "hard wiring";
flexible armored or
nonmetallic shielded copper cable (when local code
allow it) or by means of a power supply cord kit.
Risk of fire or electrical
shock exists
if an incorrect size range cord kit is used, the
Installation
Instructions
are not followed,
or the
strain relief bracket
is discarded.
For mobile homes, new installations or recreational
vehicles, use only a power supply kit designed for a
range at 125V/250V 30A. Cord must have either 3
(when local code permits grounding through neutral) or
4 conductors. Terminal on end of wires must be either
closed loop or open spade lug with upturned ends. Cord
must have strain-relief clamp.
Do not loosen the nuts which secure
the factory=installed
range wiring
to terminal
block
while
connecting
range. Electrical failure
or loss of
electrical
connection
may occur.
This appliance
is manufactured
with
the frame grounded
by connection
of a grounding
strap between
the neutral
power supply terminal
and the frame.
If used in USA, in a new branch
circuit installation
(1996 NEC), mobile
home or
recreational
vehicule,
where
local code do not
permit grounding
through
neutral
(white)
wire
or in Canada; remove the grounding
strap from
the frame and cut the other end, near the neutral
terminal.
Connect the appliance
in usual manner.
Electrical
Shock
Hazard
• Electrical
ground
is required
on this appliance.
• Do not connect to the electrical
supply
until
appliance
is permanently
grounded.
• Disconnect
power to the circuit
breaker or fuse
box before
making the electrical
connection.
• This appliance
must be connected to a grounded,
metallic,
permanent
wiring
system, or a
grounding
connector
should be connected
to the
grounding
terminal
or wire lead on the appliance.
Failure to do any of the above could result in a
fire, personal
injury
or electrical
shock.
NOTE: Range is shipped from factory with 1 1/8" dia. hole
as shown in figure 3. If a larger hole is required, punch out
the knockout.