INSTALLATION
1. Dryer MUST
be exhausted
outside
(outdoors,
not beneath
the
mobile
home)
using
metal
ducting
that
will
not
support
combustion.
Metal
ducting
must
be 4 inches (10.16
cm) in
diameter
with
no obstructions.
Rigid metal duct is preferred.
2.
If dryer is exhausted
through
the floor
and area beneath
the
mobile
home is enclosed,
the exhaust
system MUST terminate
outside
the enclosure
with
the termination
securely fastened
to the mobile
home structure.
3. When
installing
a gas dryer into
a mobile
home,
a provision
must be made for outside
make up air. This provision
is to be
not less than twice the area of the dryer exhaust
outlet.
4. This dryer
MUST
be fastened
to the
floor.
Mobile
Home
Installation
Kit No. 346764
is available
from your
dealer.
5.
Refer
to pages
2 and
3 for
other
important
venting
requirements.
6.
Installation
MUST
conform
to current
Manufactured
Home
Construction
& Safety Standard
(which
is a Federal Regulation
Title 24 CFR-Part 32-80) or when such standard
is not applicable,
with
American
National
Standard
for Mobile
Homes.
The dryer
is designed
under
ANSI Z 21.5.1
or
ANSI/UL2158
- CAN/CSA
C22.2 (latest
editions)
for HOME
USE
only.
UNPACKING
1. Using a rug, blanket
or a piece of cardboard
packing
to protect
the floor,
carefully
lay the dryer on its left side and remove the
foam
shipping
base.
2.
Return the dryer to an upright
position.
FOAM
SHIPPING
_ING
:
¸¸¸DO
ii
i
DON'T
Correct
Incorrect