PRE-INSTALLATION
REQUIREMENTS
Tools and Materials
Required
for Installation:
1. Phillips head screwdriver.
2. Channel-lock
adjustable pliers.
3. Carpenter's
level.
4. Flat or straight
blade screwdriver.
5. Duct tape.
6. Rigid or flexible metal 4 inch (10.2 cm) duct.
7. Vent hood.
8. Pipe thread
sealer (Gas).
9. Plastic knife.
ELECTRICAL
REQUIREMENTS
ELECTRIC Dryer
CIRCUIT - individual 30 amp. branch circuit fused with 30 amp. minimum
time delay fuses or circuit breaker.
POWER SUPPLY - 3 wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating
Current.
POWER SUPPLY CORD KIT - The dryer MUST employ a 3-conductor power
supply cord NEMA 10-30 type SRDT rated at 240 volt AC minimum, 30 amp.,
with 3 open end spade lug connectors with upturned
ends or closed loop
connectors OR a 4-conductor
power supply cord NEMA 14-30 type SRDT or
ST (as required) rated at 240 volt AC minimum, 30 amp., with 4 open end
spade lug connectors with
upturned
ends or closed loop connectors and
marked for use with clothes dryers. If being installed in a new branch circuit
installation, manufactured (mobile) home, recreational vehicle or area which
prohibits grounding through the neutral conductor, the dryer MUST employ
a 4-conductor power supply cord NEMA 14-30 type SRDT or ST (as required)
rated at 240 volt AC minimum, 30 amp., with 4 open end spade lug connectors
with
upturned
ends or closed loop connectors
and marked for use with
clothes dryers. See ELECTRICAL CONNECTIONS for additional instructions.
CANADA - A 4 wire power cord is installed on dryer.
OUTLET RECEPTACLE-
NEMA 10-30R (3-wire) receptacle or NEMA 14-
30R (4-wire) receptacle to be located so the power supply cord is accessible
when the dryer is in the installed position.
NEMA 10-30R
NEMA 14-30R
i
GAS Dryer
i
CIRCUIT- Individual 15 amp. branch circuit fused with a 15 amp. maximum
time delay fuse or circuit breaker.
POWER SUPPLY - 3 wire, 120 volt single phase, 60 Hz, Alternating
Current.
POWER SUPPLY CORD - The dryer is equipped with a 120 volt 3-wire
power cord.
Use separately fused circuits for washers and dryers, and DO NOT operate
a washer and a dryer on the same circuit.
NOTE: Do not under any
circumstances
remove
grounding
prong
from
plug,
_ROUNDING PRONG
EXHAUST SYSTEM REQUIREMENTS
Use only 4 inch (10.2 cm) diameter (minimum) rigid or flexible metal duct and
approved vent hood which has a swing-out damper(s) that open when the
dryer is in operation. When the dryer stops, the dampers automatically
close
to prevent drafts and the entrance of insects and rodents. To avoid restricting
the outlet, maintain a minimum of 12 inches (30.5 cm) clearance between
the vent hood and the ground or any other obstruction.
The following
are specific
requirements
for proper
and safe operation
of your
dryer. Failure
to follow
these instructions
can create excessive drying
times and fire hazards.
Do not use plastic
flexible
duct to exhaust
the dryer.
Excessive lint can build up inside exhaust system and create a fire hazard and
restrict air flow. Restricted air flow will increase dryer times. If your present
system is made up of plastic duct or metal foil duct, replace it with a rigid or
flexible metal duct
Ensure the present
duct is free of any lint prior to
installing
dryer duct.
If the dryer is not exhausted
outdoors,
some fine lint
will be expelled
into the laundry area. An accumulation of lint in any area
of the home can create a health and fire hazard.
The dryer
exhaust
system
MUST be exhausted
to the outside
of the dwelling!
Do not allow
combustible
materials
(for
example:
clothing,
draperies/curtains,
paper)
to come in contact
with
exhaust
system. The dryer MUSTNOT
be exhausted into a chimney, a wall, a ceiling,
or any concealed space of a building which can accumulate lint, resulting in
a fire hazard.
Exceeding the length
of duct pipe or number of elbows
allowed
in the "MAXIMUM
LENGTH" charts can cause an accumulation
of lint in the exhaust system. Plugging the system could create a fire hazard,
as well as increase drying times.
Do not screen the exhaust
ends of the vent system,
nor use any screws or rivets to assemble
the exhaust
system.
Lint can
become caught in the screen, on the screws or rivets, clogging the duct work
and creating a fire hazard as well as increasing drying times. Use an approved
vent hood to terminate the duct outdoors, and seal all joints with duct tape.
All male duct pipe fittings MUST be installed downstream with the flow of
air.
Explosion
hazard.
Do not
install
the dryer
where
gasoline
or other flammables
are kept or stored.
If the dryer is installed
in a garage, it must be a minimum of 18 inches (45.7 cm) above the floor.
Failure to do so can result in death, explosion, fire or burns.
Number
of
90 °
Turns
0
1
2
3
4
Number
of
90 °
Turns
0
1
2
3
MAXIMUM
LENGTH
of 4" (10.2 cm) Dia. Rigid Metal
Duct
VENT HOOD TYPE
(Preferred)
(10.2 cm)
60 ft.
52 ft.
44 ft.
32 ft.
28 ft.
Louvered
(18.28 m)
(15.84 m)
(13.41 m)
(9.75 m)
(8.53m)
MAXIMUM
LENGTH
(6.35 cm)
4s ft !14_3 m!
40 ft./12.19
m_
32 ft. (9.75 m)
24 ft. (7.31 m)
16 ft.
(4.87 m)
of 4" (10.2 cm) Dia. Flexible Metal
Duct
VENT HOOD TYPE
(Preferred)
Louvered
(10.2 cm)
30 ft.
(9.14 m)
22 ft.
(6.71 m)
14 ft.
(4.27 m)
(6.35 cm)
18 ft. (5149 m)
14ft. (4.27 m!
loft.
(3.05 m!
NOT RECOMMENDED
2