[Step 2] Install Water Line - Monogram ZFSB25DSS Installation Instructions Manual

Free-standing side-by-side stainless steel refrigerator
Table of Contents

Advertisement

Installation instructions
[STEP 1] ALL MODELS
(continued}
REINSTALL DOORS
To move the refrigerator indoors:
* Place a piece ot the carton or sott cloth against the
side panel of the refligerator
to pad and protect the
stainless steel finish.
* Place the refrigerator
on the handtruck
with a side
against the truck only.
* Move the refi_igerator indoors.
Retbr to the illustration
on page 5 or 6.
,b Carehfll>
route
the water line tubing
and
electrical
through
the fl'eezer
side bottom
hinge.
Lower the door
onto
bottom
hinge.
* Secm'e
top hinge.
* Insert
the tubing
all the way into
the coupler.
* Reconnect
the wiring
harness.
* P.eplace
top filler strip
(on model
ZFSB26).
* Replace
top cap with original
screws and springs
(where
present).
HINT:
Llse tape
or Perma
Gum to prevent
the spring
fl'om sliding
off the screw
(on model
ZFSB26).
Follow the same procedure
to reinstall
the fi'esh food door.
[STEP 2] iNSTALL WATER LiNE
* A cold water supply
is required
fl)r automatic
icemaker
operation.
The water pressm'e
must
be
between
40 and
120 p.s.i.
* Route
l/4"
OD copper
tubing
between
house
cold
water line and
the water connection
location.
* Measure
the distance
ti'om the water
x;dve on the
back of the reti'igerator
to the water supply
line.
Add 8 fl_ot length
to allow the refligerator
to be
moved
away fl'om
the wall after installation.
Bend
the robing
into 3 coils of about
10".
NOTE:
The only GE approved
plastic
tubing
is
supplied
in GE SmartConnect'"
Refrigerator
Tubing
kits. Do not use any other
plastic
water supply
line
because
the line is under
pressure
at all times.
Certain
types of plastic
will crack or rupture
with age and cause
water
damage
to your home.
GE Sma*_Comlect
_"Refiigerator
Tubing
Kits are
a_ailable
in the fl_llowing
lengths:
2' (.6 m)
- WX08X10002
6' (1.8 m)
- WX08X10006
15' (4.6 m)
- WX08X10015
25' (7.6 m)
- WX08X10025
SaddleType
Shutoff_e
Packing
Outlet Valve
Compression Nut
\
Ferrule
(Sleeve)
* Drill a 1/4"
hole in the water
pipe.
* Fasten
the shut-off
valve to the pipe with pipe clamp.
* Tighten
the clamp
screws until the sealing
washer
begins
to swell. Do not over tighten.
* Place
a compression
nut and ferrule
(sleeve)
onto
the
end of the tubing
and
comlect
it to the shut-off
_dve.
Make sine the tubing
is fully insel_ed
into the valve and
ferrule
is tightened.
* Turn
on the main
water supply
and flush debris.
Run about
a quart
of water through
the robing
into a
bucket.
Shut oil water supply
at the shut-oil
x;dve.
Shut off the matin water supply.
Turn
on the nearest
flmcet
long
enough
to clear
the
line of water.
* Install
a shut-off
vah'e between
the icemaker
water
x:dve and cold water pipe in a basement
or cabinet.
The shut-off
x:dve should
be located
where
it will be
easily a ccessible.
NOTE:
It is best to install
the x:dve into a vertical
water
pipe.
If you install
the _alve into a horizontal
water
pipe,
make
the com, ection
at the top or side to aw)id
drawing
off any sediment
fi'om the water pipe.
NOTE:
Saddle
type shut-off
valves are included
in many
water supply
kits. geflwe
purchasing,
make
sure a saddle
Vpe _;dve complies
with your local plumbing
codes.
NOTE: Commonwealth
of Massachusetts
Plumbing
Codes 248CMR shall be adhered
to. Saddle valves are
illegal and use is not permitted
in Massachusetts.
Consult with your licensed
plumber.
7