Download Print this page

Omnitron Systems Technology iConverter User Manual page 9

2-module power chassis
Hide thumbs Also See for iConverter:

Advertisement

3.4 DC Powered Chassis Mounting
Locate the DC circuit breaker of the external power source, and switch the circuit
breaker to the OFF position.
Prepare a power cable using a three conductor insulated wire (not supplied)
with a 14 AWG gauge minimum. Cut the power cable to the length required.
Strip approximately 3/8 of an inch of insulation from the power cable wires.
Connect the power cables to the
ends to the DC power connector.
WARNING: Note the wire colors used in making the positive, negative and ground
connections. Use the same color assignment for the connection at the circuit
breaker.
Connect the power wires to the circuit breaker and switch the circuit breaker ON. If
any modules are installed, their Power LED should indicate the presence of power.
Fig. 7 Rear of 2-Module Chassis with DC Power Connector
NEVER ATTEMPT TO OPEN THE CHASSIS OR SERVICE THE
POWER SUPPLY OR FAN MODULE. OPENING THE CHASSIS
THERE ARE NO USER REPLACEABLE OR SERVICEABLE
WARNING!!!
MAY CAUSE SERIOUS INJURY OR DEATH.
PARTS IN THIS UNIT.
iConverter
Chassis by fastening the stripped
Page 9

Advertisement