GASCONVERSIONS
Explosion Hazard
Use a new CSA International
approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified
person include:
licensed heating personnel,
authorized
gas company personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion, or fire.
NOTE: Gas conversions (from natural gas to LP gas or from LP
gas to natural gas) must be done by a qualified person.
_
_
...................................
C
B
......... _hutoff
valvein "closed"position
/
_
B. Gassupplyline
C. Torange
2. Open broiler door and remove broiler pan. The gas pressure
regulator is located in the back right hand corner of the broiler
corn partment.
IMPORTANT: Do not remove the gas pressure regulator.
A. Gaspressureregulator
NOTE: Do not remove the spring beneath the cap.
3. Remove the cap from the gas pressure regulator using a flat
blade screwdriver.
4. Turn the cap over so that LP is visible.
, !i!i!i!
! _:i;ii!i'i_
iiii _i; _ii;:i; iiil ;iiii'i_
iiliil i
i1iiii
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip
bracket to rear range foot.
Reconnect
the anti-tip bracket,
if the range is moved.
Failure to follow
these instructions
can result in death
or serious
burns to children
and adults.
5. Reinstall the cap.
A. Cap
A. Cap
..... A
A
To Convert
Gas Pressure
Regulator
1. Ensure that the manual shutoff valve is in the closed position.