Commercial dryer- or electric

Advertisement

Direct
Wire,
Three=wire
electrical
connection:
Three wire with ground wire: Green or bare
wire cut short, Wire is not used, Dryer is
grounded throu( h neutral conductor.
A
1"(2,5cm)--
of wires
to
strippedof
disconnect
insulation
box
H
_
Shapeends
of wires into
a hook.
(8,9 cm)
Strip 3V2" (8_9 cm) of outer
covering from end of cable. Strip
insulation back 1" (2,5 cm). If using
3 wire cable with ground wire, cut
bare wire even with outer covering,
A. :¼" conduit connector
B. Neutral (white or center)
C. lO-gauge, 3 wire with ground wire in
flexible metallic conduit
Use this method where mocal codes permit
connecting
cabinet-ground
conductor
to
neutral wire:
5, Loosen or remove center terminal block
screw.
6, Place the hooked end of the neutral wire
(white or center) of direct wire cable
under the center screw of the terminal
block (hook facing right). Squeeze
hooked end together. Tighten screw.
7, Place the hooked ends of the other
direct wire cable wires under the outer
terminal block screws (hook facing right).
Squeeze hooked ends together. Tighten
screws.
8, Insert tab of terminal block cover into
slot of dryer rear panel. Secure cover
with hold-down screw.
"C
A. External ground conductor screw
B. Center terminal block screw
C. Outer terminal block screws
D. Neutral (center wire)
Use this method where mocal codes do
not permit connecting
cabinet-ground
conductor
to neutram wire:
5, Remove center terminal block screw.
6, Remove the appliance ground wire (green
with yellow stripes) from the external
ground conductor screw. Connect
appliance ground wire and the neutral wire
(white or center) of the direct wire cable
under the center, silver-colored terminal
block screw. Tighten screw.
7, Connect the other wires to outer terminal
block screws. Tighten screws.
8, Insert tab of terminal block cover into slot
of dryer rear panel. Secure cover with hold-
down screw.
9, After reattaching the terminal cover,
connect a separate copper ground wire
from the external ground connector screw
to an adequate ground.
If codes permit and a separate ground wire is
used, it is recommended
that a qualified
electrician determine that the ground path is
adequate.
A. Separate copper ground wire
B. External ground conductor screw
C. Appliance ground wire
D. Center terminal block screw
E. Outer terminal block screws
F. Neutral (center wire)
2,
Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in
dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured to
exhaust hood with a 4" (10.2 cm) clamp.
Move dryer into final _osition. Do not crush or kink vent. Make
sure dryer is level
With dryer in final position place level on top of the dryer, first
side to side; then front to back. If the dryer is not level, adjust
the legs of the dryer up or down until the dryer is level.
2, Plug in dryer or reconnect power.
3, Check dryer operation (some accumulated
time may be on
the timer due to factory testing).
Insert coins in slide and press slide in slowly. (Operating time
will accumulate per number of coins and type of timing cam
used.) Push START/RESTART button. Using a full heat cycle
(not the air cycle), let the dryer run for at least five minutes.
Dryer will stop when time is used up.
NOTE: Dryer door must be closed for dryer to operate. When
door is open, dryer stops, but timer continues to run. To
restart dryer, close door and push START/RESTART button.
4, If drying time is too long, make sure lint screen is clean.
5, Now start the dryer and allow it to complete a full heat cycle
(not air cycle) to make sure it is working properly.