Commercial dryer- or electric

Advertisement

Power
Supply
Cord,
Use this method where local cedes permit connecting
Three-wire
electrical
connection_
cabinet-ground
conductor
to neutral w{re:
A
This blade connected
to
B
A. Spade terminals with upturned ends
B. Ring terminals
C. Neutral (white or center)
D. 3/4"UL-listed strain relief
E. Neutral
Three-wire power supply cord must
have three, No.-10 copper wires and
match a three-wire receptacle of NEMA
Type 10-30R.
5, Loosen or remove center terminal block
screw.
6, Connect the neutral wire (white or center)
of power supply cord to the center, silver-
colored terminal screw of the terminal
block. Tighten screw.
7, Connect the other wires to outer terminal
block screws. Tighten screws.
8, Tighten strain relief screws.
9, insert tab of terminal block cover into slot
of dryer rear panel. Secure cover with
hold-down screw.
E
_
C
A. External ground conductor screw
B. Center terminal block screw
C, Outer terminal block screws
D, Strain relief screw
E. Neutral (center wire)
Use this method where local codes do not permit
connecting
cabinet-ground
conductor
to neutral wire:
5, Remove center terminal block screw.
6, Remove the appliance ground wire (green
with yellow stripes) from the external
ground conductor screw. Connect
appliance ground wire and the neutral
wire (white or center) of the power supply
cord under the center, silver-colored
terminal block screw. Tighten screw.
7, Connect the other wires to outer terminal
block screws. Tighten screws.
8, Tighten strain relief screws.
9, Insert tab of terminal block cover into slot
of dryer rear panel. Secure cover with
hold-down screw.
10, After reattaching the terminal cover,
connect a separate copper ground wire
from the external ground conductor screw
to an adequate ground.
If codes permit and a separate ground wire is
used, it is recommended that a qualified
electrician determine that the ground path is
adequate.
D
F ..........
'_
E
A. Separate copper ground wire
B, External ground conductor screw
C, Appliance ground wire
D. Center terminal block screw
E, Outer terminal block screws
F. Strain relief screw
G. Neutral (center wire)
14