Parts supplied:
Leveling legs (4)
Parts package is located in dryer drum. Check that all parts
are included.
Parts needed:
Check local codes. Check existing electrical supply and venting,
and read "Electrical Requirements"
and "Venting Requirements"
before purchasing parts.
Mobile home installations require metal exhaust system
hardware, available for purchase from the dealer from whom
you purchased your dryer. For further information,
please
reference the "Assistance
or Service" section of your "Use and
Care Guide".
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with
clothes dryers. The kit should contain:
[]
A UL listed 30-amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be
at least 4 ft. (1.22 m) long. The wires that connect to the
dryer must end in ring terminals or spade terminals with
upturned ends.
[]
A UL listed strain relief.
Location Requirements
Explosion Hazard
Keep flammable
materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (460 ram) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need:
[]
A location allowing for proper exhaust installation.
See "Venting Requirements."
[]
A separate 30 amp circuit.
[]
If you are using power supply cord, a grounded electrical
outlet located within 2 ft. (610 mm) of either side of dryer.
See "Electrical Requirements."
[]
A sturdy floor to support the total weight (dryer and load)
of 200 Ibs. (90.7 kg). The combined weight of a companion
appliance should also be considered.
[]
Level floor with maximum slope of 1" (25 mm) under entire
dryer. (If slope is greater than 1" [25 mm], install Extended
Dryer Feet Kit, Part Number 279810.) If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
Do not operate your dryer at temperatures
below 45°F (7°C). At
lower temperatures,
the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
installation
clearances:
The location must be large enough to allow the dryer door
to open fully.
Dryer
Dimensions
JJ-"
(660 ram)
_ _29"
"\
"273/4'_'_
_
-_
_'
d3_;
ram)
(705 ram}
..... _-
if:3f
ram}
A
B
433/s '' I
I I--7"
_.
| _-_
433/8"
I
Ir-_f---'------_
II
(t_°2m_)l
l I/
_1/
X II (_02mm)l
II/
_ll
i I
Ill
Ill
_11
I
II(
2_1 133_"
I
I tl
Jl[
IIII
I
II\
_jJ(349
mm
4
_
"273/4
"27;/i
(705 mrn)
X _'%)1,_.29
,,
-\"
(705 turn) _, ,_i"""_-29"
"\
c
D
A. Large opening side-swing door
B. Large opening side-swing
door
C. Wide opening side-swing
door
D. Wide opening hamper door
*Most installations require a minimum 5V2" (140 mm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."