Kenmore 29" Installation Instructions Manual page 10

29" wide electric models

Advertisement

Available languages

Available languages

Direct
Wire Connection
Direct wire strain relief
Unscrew the removable conduit connector (A) and any
screws from a 3/4" (19 mm) UL listed strain relief (UL marking
on strain relief). Put the threaded section of the strain relief
(C) through the hole below the terminal block opening (B).
Reaching inside the terminal block opening, screw the
removable conduit connector (A) onto the strain relief threads.
to strain relief
4owire
Direct
Wire Connection
IMPORTANT:
A 4-wire connection is required for mobile
homes and where local codes do not permit 3-wire
connections.
f-I_ . Prepare
your 4-wire cable for
direct connection
(127
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable,
leaving bare ground wire at 5" (127 mm). Cut 11/2'' (38 mm)
from remaining 3 wires. Strip insulation back 1" (25 mm).
Shape ends of wires into hooks.
Put direct wire cable through the strain relief. The strain
relief should have a tight fit with the dryer cabinet and be in
a horizontal position. Tighten strain relief screw against the
direct wire cable.
If your wiring
looks like this:
4-wire direct connection:
Go to "4-Wire Direct Connection"
on
this page.
Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).
3-wire direct connection:
Go to "3-Wire Direct Connection"
on
page 11.