50 Model 925 Owner's Manual
The next series of displays shows the current analog reading for each security zone input. The
displays show the readings for zones 1-32.
1=147
4=146
THROUGH
31=148
Normal loop readings are between 137 - 157 with all zones secured. Each reading should be
changing only by two or three counts from its average steady reading. When a door or window is
opened, the reading will go up to a value that represents that zone is open.
This feature can be used to monitor the quality of the zone wiring and contacts. If the numbers
begin to deviate from their original values when the system was new, wiring problems that will
eventually lead to trouble or false alarms may be developing. You may wish to record the Status
Test values for future reference.
5 = TEMP (TEMPERATURE)
The Temperature Status menu allows you to view and scroll through the status of each Thermostat
and Temperature Sensor. To enter the Temperature menu, from the Status menu, press the 5 key
on the keypad. The system will display:
TSTAT 1
HEAT:60
You may enter a unit number to start displaying the status with that unit, or simply press the down
arrow key to scroll through the list of temperature zones. The status display is as shown under
Temperature Control, except that now the arrow keys may be used to continue scrolling.
TSTAT 1
MODE: AUTO
At this point, you may press the ' # ' key to control the temperature zone as specified under
Temperature Control.
2=148
3=147
5=146
6=147
32=147
TEMP:80
COOL:82
FAN: AUTO