Lamp Schedule; Osd Display; Power On Adjustment; Temperature Control - Samsung PE40C Manual

Hide thumbs Also See for PE40C:
Table of Contents

Advertisement

7
System

7.13.8 Lamp Schedule

Enables the lamp value to be adjusted to a user-specified value at a specified time in MDC mode.
Off
/
On

7.13.9 OSD Display

Displays or hides a menu item on the screen.
Source OSD

7.13.10 Power On Adjustment

You can set the warm-up time for the screen to turn on after the power button is pressed. (Range: 0 – 50
seconds)
A warm-up time that is too short may damage the product due to overvoltage.

7.13.11 Temperature Control

This function detects the internal temperature of the product. You can specify the temperature range that
is acceptable.
The default temperature is set to 77 C.
The recommended operating temperature for this product is 75 to 80 C (based on an ambient
temperature of 40 C).
The screen will become darker if the current temperature exceeds the specified temperature limit. If the
temperature continues to rise, the product will power off to prevent overheating.
/
No Signal OSD
/
MDC OSD