Enviro Windsor Owner's Manual

Enviro Windsor Owner's Manual

Pellet stove
Hide thumbs Also See for Windsor:

Advertisement

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
PELLET STOVE
WINDSOR
OWNER'S MANUAL
Contact your building or fire officials about restrictions and installation
inspection requirements in your area.
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION
AND USE OF THIS PELLET-BURNING ROOM HEATER. FAILURE TO
FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY
DAMAGE, BODILY INJURY OR EVEN DEATH.
50-038

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Windsor and is the answer not in the manual?

Questions and answers

Summary of Contents for Enviro Windsor

  • Page 1 SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE PELLET STOVE WINDSOR OWNER’S MANUAL Contact your building or fire officials about restrictions and installation inspection requirements in your area.
  • Page 2: Table Of Contents

    Table of Contents Introduction......................3 Pellet Quality....................3 Rating Label Location..................3 Important Safety Data..................4 Safety Warnings And Recommendations............4 Operating Instructions....................6 Automatic Safety Features................6 Control Board Functions..................6 Operating Your Pellet Stove................7 Turning Your Pellet Stove Off................7 Routine Cleaning and Maintenance................8 Installation......................11 Deciding Where to Locate your Pellet Appliance..........11 Removing Pellet Stove From Pallet..............11 Dimensions....................12 Clearances to Combustibles................12...
  • Page 3: Introduction

    UALITY Pellet quality is important, please read the following: Your enviro pellet stove has been designed to burn wood pellets only. Do not use any other type of fuel, as this will void any warranties stated in this manual. The performance of your pellet stove is greatly affected by the type and quality of wood pellets being burned.
  • Page 4: Important Safety Data

    To prevent the possibility of a fire, ensure that the appliance is properly installed by adhering to the installation instructions. An ENVIRO dealer will be happy to assist you in obtaining information with regards to your local building codes and installation restrictions.
  • Page 5 GLASS: Do not abuse the glass by striking or slamming the door. Do not attempt to operate the stove with broken glass. The stove uses ceramic glass. Replacement glass must be purchased from an ENVIRO dealer. Do not attempt to open the door and clean the glass while the unit is in operation or if glass is hot.
  • Page 6: Operating Instructions

    Operating Instructions UTOMATIC AFETY EATURES Your pellet Stove has the following safety features: A) The stove will shut off when the fire goes out and the exhaust temperature drops below 120 °F (49°C). B) The stove has a high temperature safety switch. If the temperature on the hopper reaches 200 °F (93 °C) the auger will automatically stop, and the stove will shut off when the exhaust temperature cools.
  • Page 7: Operating Your Pellet Stove

    Operating Instructions PERATING ELLET TOVE PRE-BURN INSTRUCTIONS: The burn pot liner holes must be clear and the liner installed correctly against the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit. DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN. MANUAL MODE: To START: Press the ON / OFF button.
  • Page 8: Routine Cleaning And Maintenance

    Routine Cleaning and Maintenance The following list of components should be inspected and maintained routinely to ensure that the appliance is operating at its optimum and giving you excellent heat value: 2-3 Days / Weekly Semi-annually or 2 Tons of Fuel Burn Pot and Liner Exhaust Vent Ash Pan...
  • Page 9 ASH PAN AND DOOR GASKETS (weekly) After extended use the gasketing may come loose. To repair this, glue the gasketing on using high- temperature fiberglass gasket glue available from your local ENVIRO dealer. This is important to maintain an airtight assembly.
  • Page 10 All surfaces should be wiped down periodically with a damp cloth. REPLACING DOOR GLASS It is recommended that your ENVIRO dealer replace the glass if broken. The door glass is made of high temperature PYRO CERAMIC 5 mm thick. The center panel is 18.5 x 13.5 inches (46.99 cm x 34.29 cm) and must be replaced with (PART # 20-023).
  • Page 11: Installation

    EMOVING ELLET TOVE ALLET Remove screws from the two (2) hold-down brackets that secure the Windsor to the pallet. Lift the brackets up to unhook from the chassis. Hold-down brackets. Figure 5: Removing Freestanding Stove From the Pallet.
  • Page 12: Dimensions

    " " (659mm) (653mm) " (689mm) " (614mm) Figure 6: Windsor Freestanding Dimensions. LEARANCES TO OMBUSTIBLES These dimensions are minimum clearances but it is recommended that you ensure sufficient room Back wall for serving, routine cleaning and maintenance. Adjacent 3"...
  • Page 13: Alcove Clearances

    Installation LCOVE LEARANCES This unit may be installed in an alcove. Maintain the clearances to combustibles shown in Figure 8. Minimum Width 48" (1219mm) Install vent at clearances specified by the vent manufacturer. Minimum Height 48" (1219mm) Maximum Depth 36" (914mm) Figure 8: Alcove Clearances.
  • Page 14: Exhaust And Fresh Air Intake Locations

    Installation XHAUST RESH NTAKE OCATIONS INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENTING MANUFACTURER ” ” ” (214 mm) (112 mm) (326 mm) ” ” (265 mm) (216 mm) Figure 10: Inlet and Outlet Location. EXHAUST Base of unit to center of flue 10 5⁄8”...
  • Page 15: Vent Termination Requirements

    Installation ERMINATION EQUIREMENTS IT IS RECOMMENDED THAT YOUR PELLET STOVE BE INSTALLED BY AN AUTHORIZED DEALER/INSTALLER. Table 1: Use in conjunction with Figure 12 for allowable exterior vent termination locations. Letter Minimum Clearance Description 24 in (61 cm) Above grass, top of plants, wood, or any other combustible materials. 48 in (122 cm) From beside/below any door or window that may be opened.
  • Page 16: Corner Through Wall Installation

    Installation ORNER HROUGH NSTALLATION Fresh Air Intake 3" (7.5 cm) Wall thimble manufactured by pellet vent manufacturer. 3" (7.5 cm) Figure 13: Corner Installation. ORIZONTAL XHAUST HROUGH NSTALLATION Vent installation: install vent at clearances specified by the vent manufacturer. A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces, or a floor, or ceiling.
  • Page 17 Installation 10. The pipe must extend at least 12” (30 cm) away from the building. necessary, bring another length of pipe (PL type) to the outside Exhaust of the home to connect to the first section. Do 3" (75mm) or 4" (100mm) "PL"...
  • Page 18: Vertical Rise With Horizontal Termination Installation (Recommended)

    Installation ERTICAL ISE WITH ORIZONTAL ERMINATION NSTALLATION ECOMMENDED Termination cap A 45° elbow with a rodent screen may be used in place of the termination cap (or stainless 90°elbow steel termination hood). Wall framing Vertical section of vent pipe Wall strap Horizontal frame for thimble Clean out tee...
  • Page 19: Inside Vertical Installations

    Vertical Vent Pipe flashing. 8. Ensure that the rain cap is approximately 24” (610 mm) above the roof. Clean Out Tee with Pipe Adapter ENVIRO Windsor Note: All vent sections must maintain 3" (76mm) clearances to combustibles. Figure 18: Inside Vertical Installation.
  • Page 20: Outside Vertical Installations

    Installation UTSIDE ERTICAL NSTALLATIONS To accomplish a outside vertical pipe installation, follow steps 1 through 5 in the “I NSIDE ERTICAL ” section and then finish it by performing the following (refer to Figure 19). NSTALLATIONS 1. Install a tee with clean out on the outside of the house. 2.
  • Page 21: Hearth Mount Installation

    PL vent) Flexible Vent Connector (use this 5ft section of pipe to vent past the fireplace damper or smoke shelf) Fireplace Damper Location Clean Out Tee Existing Fireplace ENVIRO Windsor Figure 21: Hearth Mount - Over View.
  • Page 22: Installation With Exterior Mounted Exhaust Blower

    OUNTED XHAUST LOWER The WINDSOR can be equipped with an externally mounted exhaust blower (PART #20-070). This optional kit will include all components necessary to install the exhaust blower on any external vertical wall surface. Choose a location for your stove that meets the requirements stated in this manual and allows installation with the least amount of interference to house framing, plumbing, wiring, etc.
  • Page 23 Installation 9. Connect the wires in the stove. Re-install the left side access cover to the stove and the back grill on the exterior vent housing. 10. Set the Slider Damper as described in the I “ section. NSTALLATION LIDER AMPER ETTING NOTE:...
  • Page 24: Through Wall Vertical Installation With Exhaust Blower

    Installation HROUGH ERTICAL NSTALLATION XHAUST LOWER Refer to I and I NSTALLATION NSTALLATION WITH XTERIOR OUNTED XHAUST LOWER NSTALLATION UTSIDE ERTICAL . Ensure that vent pipe is properly secured to wall using wall straps. Maintain clearances to NSTALLATIONS combustibles on vent pipe as well as unit. Rain cap - ensure cap is at least 2' (610mm) above...
  • Page 25: Thermostat Installed

    Installation HERMOSTAT NSTALLED This control board can be placed into two (2) different modes: HI / LOW OPERATION: When the jumper J9 is not jumped then the control board is in a HI / LOW mode operation. If the unit has been placed in the HI / LOW mode, the unit will be taken to a low or idle setting when the thermostat is not calling for heat.
  • Page 26 Installation door opening). Set the slider damper so that the pressure 0.18” to 0.20” reads W.C. (44.8 to 49.8 Pa). Some fuels may require higher or lower settings. Note: Some parts have been removed in order to see components more clearly. The pressure readings are taken through a hole in the front of the firebox under...
  • Page 27: Troubleshooting

    Troubleshooting DO NOT: ● Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly. Only qualified technicians should deal with possible internal electrical failures. ● Do not remove from the firebox any screws without penetrating oil lubrication. ●...
  • Page 28: Wiring Diagram

    Troubleshooting hose from vacuum switch. Check exhaust vacuum readings by placing the open end of the vacuum hose on a Magnahelic Gauge (readings must be above 0.18” to 0.20” W.C. (44.8 to 49.8 Pa) on low fire). If the motor fails to reach a 0.10” W.C. readings, then replace the combustion blower. üPoor quality fuel –...
  • Page 29: Fuses

    Troubleshooting 6. The 200 °F ( 93 °C) high limit temperature sensor has tripped. üReset sensor and determine cause – was it convection blower failure or 160 °F ( 71 °C) temperature sensor failure? Bypass the 160 °F ( 71 °C) sensor, does the convection blower come on high? If no, replace the blower.
  • Page 30: Wiring Diagram

    Wiring Diagram White Armor Cable Supplied Black Grey F (93 High Limit Grey Temperature Black White Sensor Blue White Combustion Blower Optional Exterior Exhaust Blower Brown Power Cord F (49 Exhaust Temperature Sensor Ground Brown Black 115V 115V White Black White Black 220V...
  • Page 31: Parts List

    External Exhaust Bottom EF5-145 45° Exhaust Adaptor EF5-146 Exhaust Starter Tube 3” x 21⁄2” Long EF5-147 External Exhaust Kit (3” pipe) 20-070 Windsor Owner’s Manual - Domestic 50-038 60° Exterior Exhaust Adaptor 50-096 Door Screen 50-177 Circuit Board - 115V 50-178...
  • Page 32 Parts List Reference Description Part Number Number Door Knob - Brushed Nickel 50-262 Circuit Board Stand Offs 50-331 Air Deflector 50-363 Hose Barb Shield 50-472 Combustion/ Exhaust Blower - 115V 50-473 Stainless Steel Burn Pot Liner - Standard 50-474 Stainless Steel Burn Pot Liner - High Ash 50-587 Shafted Auger With Paddles - 115 V 50-504...
  • Page 33 Parts List Reference Description Part Number Number Cast Side Left - Diamond Black 50-234 Cast Side Left - Inferno Red 50-235 Cast Side Left - Pearl Grey 50-236 Cast Side Left - Wedgewood Blue 50-237 Cast Side Left - Westport Green 50-238 Cast Side Left - Antique Chestnut 50-862...
  • Page 34: Parts Diagram - Components

    Parts Diagram - Components WINDSOR - Components December 2004 � � �� � �� � �� � � � �� � ��...
  • Page 35: Parts Diagram - Steel & Cast

    Parts Diagram - Steel & Cast...
  • Page 36: Warranty

    Warranty Sherwood Industries Ltd. gives a five year limited warranty on all steel manufactured parts. A one-year warranty is provided on all electrical components. The above limited warranties are extended only to the original purchaser. There is no warranty on the following parts: ●...
  • Page 37: Installation Data Sheet

    Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference. NAME OF OWNER: NAME OF DEALER: _________________________________________ _________________________________________ ADDRESS: ADDRESS: _________________________________________ _________________________________________ _________________________________________ _________________________________________ _________________________________________ _________________________________________ PHONE:___________________________________ PHONE:___________________________________ NAME OF INSTALLER: MODEL:___________________________________ SERIAL NUMBER:___________________________ _________________________________________ DATE OF PURCHASE: _____________...

Table of Contents