Safety Rules - Williams 0656542.9 Owner's Manual

6,000 and 10,000 / 20,000 / 30,000 btu/hr. models blue flame unvented gas heater
Table of Contents

Advertisement

Safety Rules

WARNING: Read these rules and the instructions
carefully.
Failure to follow these rules and
instructions could cause a malfunction of the
heater. This could result in death, serious bodily
injury and/or property damage.
INSTALLATION MUST CONFORM TO LOCAL CODES. IN THE
ABSENCE
OF
LOCAL
CONFORM TO THE NATIONAL FUEL GAS CODE, ANSI Z223.1.
INSTALLATION AND REPAIR SHOULD BE DONE BY A
QUALIFIED
SERVICE
SHOULD BE INSPECTED BEFORE USE AND AT LEAST
ANNUALLY BY A PROFESSIONAL SERVICE TECHNICIAN.
MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO
EXCESSIVE LINT FROM SOME CARPETING, BEDDING
MATERIAL, ETC.
IT IS IMPERATIVE THAT CONTROL
COMPARTMENTS,
BURNERS
PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
SEE CARBON MONOXIDE WARNING ON PAGE 12.
YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED
WHEN THEY ARE IN THE SAME ROOM WITH THE
APPLIANCE.
ANY SAFETY SCREEN, GUARD OR PARTS REMOVED FOR
SERVICING AN APPLIANCE MUST BE REPLACED PRIOR
TO OPERATING THE APPLIANCE TO AVOID PROPERTY
DAMAGE, BODILY INJURY OR DEATH.
CHILDREN AND ADULTS SHOULD BE ALERTED TO THE
HAZARD OF HIGH SURFACE TEMPERATURE AND SHOULD
STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD
BE LOCATED OUT OF TRAFFIC AND AWAY FROM
FURNITURE AND DRAPERIES.
WARNING:
Any change to this heater or its
controls could cause injury or death.
Use only manufacturer's replacement parts. Use of any other
1.
parts could cause injury or death.
WARNING:
Do not use this unvented room heater if any part has been under water. Immediately call a qualified service technician to inspect the
unvented room heater and to replace any part of the control system and any gas control which has been under water.
4
CODES,
INSTALLATION
TECHNICIAN.
THE
AND
CIRCULATING
2.
Be sure the heater is for type of gas to be used. Do not
change it to use with other gases. Unsafe operation could
result and could cause bodily injury and death.
3.
It is prohibited to install the heater in a bedroom, trailer or
recreational vehicle/mobile home, etc (see exceptions on the
front page). If installed in a garage or basement, heater must
be a minimum of 24" above the floor.
4.
Use joint compound (pipe dope) on threaded joints of gas
MUST
piping that is resistant to the action of liquefied petroleum
gas.
5.
Use only ground joint unions in gas piping.
APPLIANCE
6.
Install a manual shutoff valve and union ahead of the controls
so that the controls and heater may be removed for servicing,
if necessary.
7.
Include a 1/8 NPT plugged tapping accessible for test gauge
connection immediately upstream of the gas supply
connection to the heater.
AIR
8.
Never test for gas leaks with an open flame. Use soap suds
to check all gas connections. This will avoid the possibility of
fire or explosion.
9.
Turn off heater and let cool before servicing. Only a qualified
service person should service and repair this heater.
10. DO NOT PLACE CLOTHING OR OTHER FLAMMABLE
MATERIAL ON OR NEAR THE APPLIANCE.
11. DO NOT modify or alter the heater in any way.
12. Clean the heater and periodically inspect the pilot and burner
flame as described in the maintenance section of this manual.
13. Disconnect the heater during supply line pressure testing.
14. Follow the lighting and operating procedures given in this
manual.
15. Since the vent-free gas heaters may easily increase the
amount of humidity in the room, the larger the burner size the
more humidity present. This can cause excessive moisture
accumulation on windows and other surfaces.
16. If L.P. gas is required, the L.P. supply tank must be placed
outside the house. It must be installed in a well ventilated
area away from the house. The distances must be placed as
prescribed by the law. Check local and state codes and laws
in order to comply with proper safety requirements.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents