Service
Hints
If your heater fails to work right, you may avoid inconvenience
and the cost
of a service
call by checking the following points before you call for service.
FOR YOUR SAFETY
FOR YOUR SAFETY
If you smell gas:
Do not store
or
use gasoline
1. Open windows.
or other flammable
vapors
and
2. Don't touch electrical.
liquids in the vicinity of this or any
3. Extinguish any open flame.
other appliance.
4. Immediately call your gas
supplier.
POSSIBLE CAUSE
WHAT TO DO
If your heater Is not heating or not giving enough heat --
Thermostat is not set correctly.
Reset thermostat to desired setting.
Pilot is out.
Check pilot. Relight if necessary
following instructions for "Operating
Your Heater."
Pilot is on but burnerwon't
come on.
If gas valve is set at other than "On"
heater will not operate. Shut heater
down and follow instructions for
relighting in "Operating
Your Heater"
section.
Burner is not operating
properly.
Air flow restricted.
Pilot goes out time after time --
Heater flue blocked.
Check flame. If it is yellow the burner
is not getting enough air. Or if flame
is blue and noisy and seems to lift off
the burner, the burner is getting too
much air. See page 14.
Check that doors, drapes or furniture
are not blocking heater louvers.
Locate vent outletblockage and
clean.
If bumer is noisy --
Gas input amount is incorrect.
Too much primary air.
If blower does not run --
(if equipped)
Fan switch not set.
Blower not connected to
electric power.
If blower motor is noisy --
(if equipped)
Housing rattling.
Blower dirty.
Blower wheel bent.
Contact Williams Service Department.
Contact Williams Service Department.
Select fan speed.
Connect to electricpower.
Tighten screws.
Clean blower wheel.
Straighten or replace.
See troubleshooting section for more detailed information.
How to Order Repair Parts
When ordering
repair parts, always give the following
information:
1. MODEL NUMBER
2. MFG. DATE CODE
3, PART NUMBER
4. PART DESCRIPTION
All parts listed herein may be ordered from your equip-
ment supplier.
The Model Number of your Williams room heater will be
found on the rating plate near gas valve, inside control
compartment.