4513-630, -63W, -6EW

Output bin tests

The Output bin tests setting is used to test the printer's output bins and its sensors.

Feed Tests

This test verifies that the media from the printer's default input source feeds to the specific output bin. Press
to select Single, or press
default output bin. No buttons are active during this test. The Continuous test feeds media to the default output
is pressed. The indicator light blinks green, and the operator panel displays [Select Output Bin]
bin until
Feeding... while either of these tests perform.

Sensor Test

This test verifies that the selected output bin's sensors are working correctly. The following sensors are available
in each output bin:
Output bin
Standard bin
-bin Mailbox
*This sensor will register the following levels: "empty," "normal," "near full," and "full.
Press
to select this test from the Output bin tests menu, and then press
output bin. Closed will display on the operator panel if the sensor is closed. Open will display on the operator
panel if the sensor is open. If the wrong message is displayed, then the sensor is malfunctioning. To exit the
Sensor Test, press

Base Sensor Test (B. Sensor Test)

The Base Sensor Test verifies the correct functioning of the following sensors:
This test toggles each of these sensors. If a sensor does not toggle, then the sensor is malfunctioning. To exit
the Base Sensor Test, press
3-12
Service Manual
to select Continuous. The Single test feeds one sheet of media to the
and
Full sensor
Near full sensor
x
x
x
or
.
Toner level open
Input open
Exit open
Narrow media open
Front door open
or
.
Passthru 1
Passthru 2
sensor
sensor
x
x
again to select the desired
Level sensor*
x