R
C. Blower Replacement
1. Remove the 2 screws from the Blower Housing Assem-
bly using a 5/32 allen wrench. Figure 23.1.
2. Disconnect the wires from the blower.
3. Remove the 2 screws from the hold down bracket and
pull the blower and bracket forward.
4. Remove the blower from the hold down bracket.
5. Re-install in reverse order. Be certain that the hold down
bracket's screws are completely seated in the grom-
ments. Insert the locating tab in the hold down bracket
into the placement slot.
Blower Housing Assembly
Remove Screws & Pull
Blower Housing Assembly
away from Insert
Figure 23.1
September 15, 2011
Hold Down
Bracket
7045-178
Shock Risk.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front of appliance.
Fire Risk.
Do NOT allow hot coals or embers to overflow ash lip
May melt protective wire coating on fan power
cord causing electrical short, fire or injury
Remove Screws from Hold Down
Bracket and Pull Forward