Grizzly G1012 Instruction Manual page 27

18" heavy-duty bandsaw
Hide thumbs Also See for G1012:
Table of Contents

Advertisement

NOTICE
If setting table tilt to the left, it will be nec-
essary to remove the positive stop.
To adjust the positive stop so the table will be
90° to the blade:
1.
Loosen the two plastic knobs and check-nut
that secure the positive stop adjusting bolt
shown in Figure 32.
2.
Raise the upper blade guide assembly and
place a 6" machinist's square or try-square
on the table next to the side of the blade.
Adjust the positive stop adjusting bolt to
raise or lower the table until the table is 90˚
to the blade.
Figure 32. Squaring table to blade.
3.
Secure the plastic knobs and lock the posi-
tive stop adjusting bolt by tightening the
check-nut. Ensure that the bolt does not turn
while tightening the check-nut.
To adjust the miter slot parallel to the band-
saw blade:
1.
Loosen the six trunnion bolts underneath the
table.
2.
Place a good straightedge along the blade.
The straightedge should touch the front and
the back of the blade. Use a fine ruler to
gauge the distance between the blade and
the miter slot as shown in Figure 33. The
distance you measure should be the same at
both the front and the back of the table.
G1012 18" Bandsaw
Figure 33. Squaring table to blade.
3.
Adjust the table in the desired direction and
secure in position by retightening the trun-
nion bolts.
The table should also be 90˚ to the back of the
blade as shown in Figure 34. If you should find
that the table is not perpendicular to the back of
the blade, shim the table in the desired direction
by placing washers between the table and the
two trunnions.
Remove the trunnion bolts and add washers so
the table tilts in the desired direction. Electrical
washers are very thin and will allow fine adjust-
ment.
Figure 34. Squaring table to blade back.
-25-