Table 2. Numeric error codes (continued)
Symptom or error
2102
Initialization error on HDD1 (Ultrabay hard disk drive)
2110
Read error on HDD0 (Main hard disk drive)
2112
Read error on HDD1 (Ultrabay hard disk drive)
Error messages
Table 3. Error messages
Symptom or error
Device address conflict.
Allocation error for device.
Failing bits: nnnn.
Invalid system configuration data.
I/O device IRQ conflict.
Hibernation error.
Fan error.
Thermal sensing error.
FRU or action, in sequence
1. Reseat the hard disk drive.
2. Ultrabay™ hard disk drive.
3. System board.
1. Reseat the hard disk drive.
2. Main hard disk drive.
3. System board.
1. Reseat the hard disk drive.
2. Ultrabay hard disk drive.
3. System board.
FRU or action, in sequence
1. Load "Setup Defaults" in the BIOS Setup Utility.
2. Backup battery.
3. System board.
1. Load "Setup Defaults" in the BIOS Setup Utility.
2. Backup battery.
3. System board.
1. DIMM.
2. System board.
1. DIMM.
2. System board.
1. Load "Setup Defaults" in the BIOS Setup Utility.
2. Backup battery.
3. System board.
1. Restore the system configuration to what it was
before the computer entered hibernation mode.
2. If memory size has been changed, re-create the
hibernation file.
1. Fan.
2. Thermal grease.
3. System board.
System board.
Chapter 4
.
Related service information